Mixing in microchannels based on hydrodynamic focusing and time-interleaved segmentation: modelling and experiment.

نویسندگان

  • Nam-Trung Nguyen
  • Xiaoyang Huang
چکیده

This paper theoretically and experimentally investigates a micromixer based on combined hydrodynamic focusing and time-interleaved segmentation. Both hydrodynamic focusing and time-interleaved segmentation are used in the present study to reduce mixing path, to shorten mixing time, and to enhance mixing quality. While hydrodynamic focusing reduces the transversal mixing path, time-interleaved sequential segmentation shortens the axial mixing path. With the same viscosity in the different streams, the focused width can be adjusted by the flow rate ratio. The axial mixing path or the segment length can be controlled by the switching frequency and the mean velocity of the flow. Mixing ratio can be controlled by both flow rate ratio and pulse width modulation of the switching signal. This paper first presents a time-dependent two-dimensional analytical model for the mixing concept. The model considers an arbitrary mixing ratio between solute and solvent as well as the axial Taylor-Aris dispersion. A micromixer was designed and fabricated based on lamination of four polymer layers. The layers were machined using a CO2 laser. Time-interleaved segmentation was realized by two piezoelectric valves. The sheath streams for hydrodynamic focusing are introduced through the other two inlets. A special measurement set-up was designed with synchronization of the mixer's switching signal and the camera's trigger signal. The set-up allows a relatively slow and low-resolution CCD camera to freeze and to capture a large transient concentration field. The concentration profile along the mixing channel agrees qualitatively well with the analytical model. The analytical model and the device promise to be suitable tools for studying Taylor-Aris dispersion near the entrance of a flat microchannel.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of electrokinetic mixing in 3D non-homogenous microchannels

A numerical study of 3D electrokinetic flows through micromixers was performed. The micromixers considered here consisted of heterogeneous rectangular microchannels with prescribed patterns of zeta-potential at their walls. Numerical simulation of electroosmotic flows within heterogeneous channels requires solution of the Navier-Stokes, Ernest-Plank and species concentration equations. It is kn...

متن کامل

Comparison of Different Loop Bioreactors Based on Hydrodynamic Characteristics, Mass Transfer, Energy Consumption and Biomass Production from Natural Gas

The performance of a forced-liquid Vertical Tubular Loop Bioreactor (VTLB), a forced-liquid Horizontal Tubular Loop Bioreactor (HTLB) and a gas-induced External Airlift Loop Bioreactor (EALB) were compared for production of biomass from natural gas. Hydrodynamic characteristics and mass transfer coefficients were determined as functions of design parameters, physical properties of gases as ...

متن کامل

High-Throughput Particle Manipulation Based on Hydrodynamic Effects in Microchannels

Microfluidic techniques are effective tools for precise manipulation of particles and cells, whose enrichment and separation is crucial for a wide range of applications in biology, medicine, and chemistry. Recently, lateral particle migration induced by the intrinsic hydrodynamic effects in microchannels, such as inertia and elasticity, has shown its promise for high-throughput and label-free p...

متن کامل

The Effects of Different Levels of Canola Oil and Diet Mixing Time Length on Performance, Carcass Characteristics and Blood Lipids of Broilers

This experiment was conducted to investigate the effects of different levels of canola oil and diet mixing time length on performance, carcass traits and blood lipids in broilers. In this experiment 288 Ross-308 broilers were used from 11 up to 42 days as factorial arrangement (3×2) included three levels of canola oil (0, 3 and 6%) and two mixing time length (10 and 15 minute) in 6 treatments, ...

متن کامل

Numerical Study on Low Reynolds Mixing ofT-Shaped Micro-Mixers with Obstacles

Micromixers are one of the most crucial components of Lab-On-a-Chip devices with the intention of mixing and dispersion of reagents like small molecules and particles. The challenge facing micromixers is typically insufficient mixing efficiency in basic designs, which results in longer microchannels. Therefore, it is desirable to increase mixing efficiency, in order to decrease mixing length, w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 5 11  شماره 

صفحات  -

تاریخ انتشار 2005