Generalizing the CHOKe flow protection
نویسندگان
چکیده
This paper proposes a simple and stateless active queue management (AQM) scheme, called geometric CHOKe (gCHOKe), to protect responsive flows from unresponsive ones. gCHOKe has its root on and is a generalization of the original CHOKe. It provides an additional power of protection, achieved by introducing an extra flow matching trial following each successful flow comparison of packets. The maximum number of comparisons permitted for an arrival can be controlled by a parameter called maxcomp. The quality of flow protection improves with maxcomp. Compared to the plain CHOKe (which is just the simplest case of gCHOKe), our analysis and simulations show that the scheme can achieve over 20% improvement in the bounds of both bandwidth and buffer space used by an aggressive flow. In addition, up to 14% of the total link capacity can be saved from the unresponsive flow, allowing responsive or rate-adaptive flows to obtain a better share of resources in the router.
منابع مشابه
Modeling Critical Flow through Choke for a Gas-condensate Reservoir Based on Drill Stem Test Data
Gas-condensate reservoirs contain hydrocarbon fluids with characteristics between oil and gas reservoirs and a high gas-liquid ratio. Due to the large gas-liquid ratio, wellhead choke calculations using the empirical equations such as Gilbert may contain considerable error. In this study, using drill stem test (DST) data of a gas-condensate reservoir, coefficients of Gilbert equation was modifi...
متن کاملIntegrated Analysis of Choke Performance and Flow Behaviour in High-Rate, Deviated Gas-Condensate Wells
 Understanding the flow behaviour in a gas well is crucial for future production strategies, obtaining bottomhole conditions from wellhead production data, analyzing production data and estimating reservoir properties. In this work, the pressure profile and flow regime are studied on four wells of a multi-well, multi-layer gas-condensate reservoir, producing at high rate. The wells are deviate...
متن کاملAcute choke zone effects: Lessons from radioactive and fluorescent microspheres in a pig model muscle flap.
BACKGROUND Choke vessels dilate and contract to regulate blood flow between adjacent arterial angiosomes. In skin flap surgery, when arterial inflow to an angiosome is ligated, choke vessels allow blood supply from an adjacent angiosome. In muscle flap surgery, the vascular anatomy is analogous to skin flaps; however, while it is established that the choke vessels will fully dilate irreversibly...
متن کاملExpiratory flow limitation and the response to breathing a helium-oxygen gas mixture in a canine model of pulmonary emphysema.
The pathophysiology of reduced maximum expiratory flow in a canine model of pulmonary emphysema was studied, and the results interpreted in terms of the wave-speed theory of flow limitation. According to this theory, maximum expiratory flow is related both to the cross-sectional area and compliance at an airway site where a critical gas velocity is first reached ("choke-point") and to gas densi...
متن کاملEOS Protection Circuit for USB2 Transceiver
This paper presents CMOS integrated electrical over stress (EOS) protection circuit for USB2 transceiver. A unique full speed SE0 state in USB2 standard protocol produces overshoot and undershoots in presence of on board choke. The purpose of choke is to minimize EMI for USB2 differential signalling. This works fine as long as data signalling is differential. In the presence of SE0 state, singl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Computer Networks
دوره 57 شماره
صفحات -
تاریخ انتشار 2013