How Using Dedicated Software Can Improve RECIST Readings

نویسندگان

  • Amandine René
  • Sophie Aufort
  • Salim Si Mohamed
  • Jean-Pierre Daurès
  • Stéphane Chemouny
  • Christophe Bonnel
  • Benoit Gallix
چکیده

Decision support tools exist for oncologic follow up. Their main interest is to help physicians improve their oncologic readings but this theoretical benefit has to be quantified by concrete evidence. The purpose of the study was to evaluate and quantify the impact of using dedicated software on RECIST readings. A comparison was made between RECIST readings without dedicated application vs. readings using dedicated software (Myrian XL-Onco, Intrasense, France) with specific functionalities such as 3D elastic target matching and automated calculation of tumoral response. A retrospective database of 40 patients who underwent a CT scan follow up was used (thoracic/abdominal lesions). The reading panel was composed of two radiologists. Reading times, intra/inter-operator reproducibility of measurements and RECIST response misclassifications were evaluated. On average, reading time was reduced by 49.7% using dedicated software. A more important saving was observed for lung lesions evaluations (63.4% vs. 36.1% for hepatic targets). Inter and intra-operator reproducibility of measurements was excellent for both reading methods. OPEN ACCESS Informatics 2014, 1 161 Using dedicated software prevented misclassifications on 10 readings out of 120 (eight due to calculation errors). The use of dedicated oncology software optimises RECIST evaluation by decreasing reading times significantly and avoiding response misclassifications due to manual calculation errors or approximations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Volumetry: an alternative to assess therapy response for malignant pleural mesothelioma?

The purpose of our study was to assess robustness of volumetric measurement of malignant pleural mesothelioma (MPM) before and after chemotherapy to modified RECIST (response evaluation criteria in solid tumours) criteria. 30 patients with digitally available chest computed tomography (CT) scans before and after three cycles of chemotherapy were included. Three readers independently assessed tu...

متن کامل

Commissioning the First Mobile Dedicated Accelerator for Intraoperative Electron Radiotherapy in Iran

Introduction: Intraoperative radiotherapy is a radiotherapy technique in which a high single fraction of radiation dose is delivered to the patient after surgery and Concurrent with anesthesia time. The most frequent method for IORT implementation is Intraoperative electron radiotherapy (IOERT), in which, some dedicated and high dose per pulse electron accelerators are employe...

متن کامل

RECIST Applied to Realistic Tumor Models

RECIST (Response Evaluation Criteria in Solid Tumors) is a linear measure intended to predict tumor size in medical computed tomography (CT). In this work, using purely geometrical considerations, we estimate how well RECIST can predict the volume of randomly-oriented tumor models, each composed of the union of ellipsoids. The principal conclusion is that RECIST is likely to work less well for ...

متن کامل

Are glucose readings sufficient to adjust insulin dosage?

AIMS/HYPOTHESIS insulin therapy is effective predominantly when dosage is frequently adjusted. However, a controversy surrounds the pertinent clinical parameters required to make effective and safe frequent dosage adjustments. We hypothesize that glucose readings are sufficient to adjust insulin dosage provided that dosage is adjusted every 1-4 weeks. METHODS to test the hypothesis, we genera...

متن کامل

Test and Verification Solutions

INTRODUCTION This document describes the business benefits associated with outsourcing software testing. It is not uncommon in the software industry for developers to test their own code or for organisations to establish a dedicated in‐house testing department. The following highlights some of the issues associated with this approach, describes how TVS manages a client engagement and how an out...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Informatics

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2014