Comparison of a passive aerosol sampler to size-selective pump samplers in indoor environments.
نویسندگان
چکیده
The objective of this work was to investigate the ability of the Wagner-Leith passive aerosol sampler to measure indoor exposures over periods of 24 hours to 2 weeks. An automated analysis technique was developed so that lower aerosol concentrations could be sampled over shorter time periods. A test of the new analytical method against a manual method showed good agreement. The passive sampler was tested alongside three pump-operated, size-selective samplers in indoor environments. Generally, good correlation with the active samplers was observed. Correlation with a personal impactor with uncoated substrates was not statistically significant, but the cyclone, MS&T impactor, and overall correlations had R(2) values of 0.73-0.88. Combining these data with a previous study produced an R(2) of 0.96 between passive and active results. Large discrepancies (up to 147%) between passive and personal impactor results were observed and were attributed to particle bounce in the impactor, passive sampler imprecision due to few collected fine particles, and problems with detection of organic particles in the passive sampler. The Wagner-Leith sampler has now been tested over five orders of magnitude in mass concentration, in which it has proved useful for obtaining aerosol size distributions, mass fractions, qualitative elemental analysis, and morphology of individual particles. The sampler has several limitations, including increased sensitivity to contamination when fewer particles are collected, uncertainties in sampling semi-volatile particles, and the need for some expertise and expense to analyze the passive samples.
منابع مشابه
Performance of personal inhalable aerosol samplers in very slowly moving air when facing the aerosol source.
While personal aerosol samplers have been characterized primarily based on wind tunnel tests conducted at relatively high wind speeds, modern indoor occupational environments are usually represented by very slow moving air. Recent surveys suggest that elevated levels of occupational exposure to inhalable airborne particles are typically observed when the worker, operating in the vicinity of the...
متن کاملImproving the UNC Passive Aerosol Sampler Model Based on Comparison with Commonly Used Aerosol Sampling Methods
Objectives In an occupational environment, passive sampling could be an alternative to active sampling with pumps for sampling of dust. One passive sampler is the University of North Carolina passive aerosol sampler (UNC sampler). It is often analysed by microscopic imaging. Promising results have been shown for particles above 2.5 µm, but indicate large underestimations for PM2.5. The aim of t...
متن کاملPii: S0003-4878(99)00042-3
Existing samplers for the collection of bioaerosols have been designed with the aim of maintaining biological stability of the collected material, and in general do not select particles in accordance with international conventions for aerosol sampling. Many have uncharacterised sampling eciencies and few are designed as personal samplers. If standard personal dust samplers are used for bioaero...
متن کاملEvaluation of a passive air sampler for measuring indoor formaldehyde.
A passive air sampler, using 4-amino-3-hydrazino-5-mercapto-1,2,4-triazole, was evaluated for the determination of formaldehyde in indoor environments. Chromatography paper cleaned using a 3% hydrogen peroxide solution was experimentally determined as being the optimum absorption filter for the collection of formaldehyde (0.05 microg cm(-2) formaldehyde). From a linear-regression analysis betwe...
متن کاملPerformance Characteristics of Personal Samplers in Still and Moving Air
Personal samplers or in general blunt body samplers are widely used in occupational hygiene for collecting air contaminants in the work environments. This work is part of an ongoing research into the performance evaluation of personal samplers, particularly in terms of their aerodynamic properties. Velocity profiles have been measured around and within typical cylindrical sampling devices, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AIHA journal : a journal for the science of occupational and environmental health and safety
دوره 64 5 شماره
صفحات -
تاریخ انتشار 2003