Evaluation of Renal Function: A Comparison Between Camera-Based Tc-99m MAG3 and 24-Hour Creatinine Clearances

نویسندگان

  • Fabio P Esteves
  • Raghuveer K Halkar
چکیده

OBJECTIVE: The 24-hour creatinine clearance is the standard clinical technique to measure renal function; however, this measurement is cumbersome and inconvenient for patients. We hypothesized that a camera-based Tc-99m mercaptoacetyltriglycine (MAG3) clearance obtained simultaneously with a standard MAG3 scan would correlate well with the 24-hour creatinine clearance and could serve as a simple marker of renal function. MATERIALS AND METHODS: Data were obtained from a retrospective analysis of 28 patients with varying degrees of renal dysfunction and 85 subjects evaluated for kidney donation. The MAG3 clearance was calculated using a camera-based technique without blood or urine sampling. The creatinine clearance was measured using the plasma creatinine and a 24-hour urine collection. The MAG3 and creatinine clearances were corrected for body surface area and values in normal subjects and patients were compared using paired T-test analysis. The linear association between the MAG3 and creatinine clearances was expressed by Pearson’s correlation coefficient. RESULTS: The mean MAG3 clearance in the potential renal donors was 321 95 ml/min (95% C.I. 171-546 ml/min), significantly higher than the mean creatinine clearance of 15251 ml/min (95% C.I. 79-278 ml/min, p<0.001). The mean MAG3 clearance in patients was 15370 ml/min (95% C.I. 32-316 ml/min) and was also significantly higher than the mean creatinine clearance of 7436 ml/min (95% C.I. 21138 ml/min, p<0.001). The ratio of the mean creatinine clearance to the mean MAG3 clearance was essentially the same for volunteers and patients, 0.47 and 0.48,

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Demonstration of Adaptive Functional Differences Seen in Kidneys Accompanying a Nonfunctioning/Hypofunctioning Partner, using Camera Based Tc 99m MAG3 Clearance Measurement Technique

OBJECTIVE The aim of this study was to demonstrate the functional compensation that occurs in kidneys which accompany a partner with total or partial loss of renal functioning mass, using camera-based Tc 99m MAG3 clearance technique. MATERIAL AND METHODS Eighty five patients (43M, 42F, age: 44.8±12.6, range: 18-77 years) with normal serum creatinine levels and normal (<Grade 1) Tc 99m MAG3 re...

متن کامل

Comparison of Tc-99m Ethylenedicysteine (Tc-99m EC) with Tc-99m DPTA in evaluation of renal disease [Persian]

Tc-99m-EC is a new renal radiopharmaceutical introduced as an alternative for Tc-99m MAG3. Twenty-three normal volunteers and patients in different .stages of renal disease were evaluated with Te-99m EC and Tc-99m DTPA. The mean initial uptake of EC was significantly higher as compared to DTPA. There was a high correlation between rectangular and hand-drawn ROls for kidney and background,...

متن کامل

Derived GFR (dGFR) Values from Technetium-99m-MAG3 Data: A Comparison with the 24-Hour Creatinine Clearance

Objective: Glomerular filtration can eliminate a substance only from the filtered fraction of the renal plasma flow. Since that fraction normally is 20%, ERPF agents clear from the kidneys about five times as fast as GFR agents. In most chronic renal diseases, the filtration fraction (GFR divided by ERPF) is largely unaffected, so the GFR can be estimated by dividing the ERPF by five. The aim o...

متن کامل

Quantitative and Qualitative Scintigraphic Measurement of Renal Function in Persian Cat Using 99mTechnetium Ethylenedicysteine and 99mTechnetium Diethylenetriaminepentaacetic

Objective- To consider the use of renal scintigraphic evaluation of kidney function in Persian cat and make a comparison between 99mTechnetium ethylenedicysteine and 99mTechnetium diethylenetriaminepentaacetic in renal scintigraphy. Design- Descriptive study Animals- 6 male healthy adult Persian cats - no clinical sign of renal disorders and prior to presentation. Proce...

متن کامل

Early detection of renal scarring in children with suspected pyelonephritis: Comparison of diuretic MAG3 scintigraphy (F0) and DMSAScan

 Abstract Background: Screening for patients at risk of renal scarring is a challenge in children with acute pyelonephritis (APN). Diuretic Tc-99m mercaptoacetyltriglycine (MAG3) scintigraphy with zero time injection of furosemide (MAG3-F0) was observed to display focal parenchymal disorders. The advantages of MAG3 include: lower radiation dose and short duration of the test. The aim of this st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006