Reliability of Mid-Upper Arm Circumference Measurements taken by Community Health Nurses

نویسندگان

  • HibbAH ARAbA SAeed
  • JoSepH biRUNdU MogeNdi
  • RobeRt AkpARibo
  • pAtRiCk kolSteReN
چکیده

Mid upper arm circumference-based diagnosis of severe acute malnutrition is seen as very attractive because it is assumed to be simple to use in measuring the arm and also requires a single cut-off without having to compute an index or compare to a reference population. The circumference of the left upper arm measured at the mid-point between the tip of the shoulder and the tip of the elbow is referred to as mid upper arm circumference (MUAC). MUAC was originally used in emergency settings where huge populations had to be screened within a short time. However, in the past few years the development of community therapeutic care of acute malnutrition implied a need for a diagnostic tool. The general objective of the study was to assess the interand intra-observer variability in MUAC measurements of under-five children by community health nurses in selected communities of the Northern Region in Ghana. A community-based cohort study was conducted on a convenience sample of 120 community health nurses and nursing students from selected communities in the Northern region of Ghana. Each CHN measured MUAC for four unique children on three consecutive days to assess intra-observer variability. To assess inter-observer variability, 50 independent nursing students took MUAC measures of four children on the same day. Bland Altman plots showed a high degree of agreement of MUAC measures taken repeatedly for three days by the same observers and ICC= 0.993. MUAC measures among observers (inter-observer) and ICC =0.042 showed a considerable level of variability among different observers. This study showed that MUAC is reliable when repeated measures are taken on children by the same observers, but using different observers for the same children showed a high level of variability. key words: Mid-upper arm circumference, Reliability, Inter and intra observer variability, Community health nurses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability and accuracy of anthropometry performed by community health workers among infants under 6 months in rural Kenya

OBJECTIVE To assess the inter-observer variability and accuracy of Mid Upper Arm Circumference (MUAC) and weight-for-length Z score (WFLz) among infants aged <6 months performed by community health workers (CHWs) in Kilifi District, Kenya. METHODS A cross-sectional repeatability study estimated inter-observer variation and accuracy of measurements initially undertaken by an expert anthropomet...

متن کامل

Patterns of Maternal Weight Gain During Pregnancy and Birth Weight

Anthropometric parameters are an important indicator of health and nutritional status comprising the whole span of mans life. However, they are not of the same degree of simplicity and sensitivity in assessing the public health status. During recent decades many studies have attempted to examine the relationships of these measurements in order to present simple alternatives for similar purposes...

متن کامل

بررسی میزان و نوع ارتباط بین اندازه دور بازو با وزن (جهت تخمین وزن) در افراد بالغ و سالم ساکن شهر تهران

  The present survey is a correlation study designed to determine extent and type of relation between mid-arm   circumference and weight in order to offer a scale for assumption of weight.   390 healthy, adults who are resident in Tehran and between the ages 18-65 were selected from visitors at three   hospital censers at random. Input accumulation was carried out by means of a questionnaire an...

متن کامل

Is Mid-upper Arm Circumference Alone Sufficient to Identify Severe Acute Malnutrition Correctly?

Anthropometric data of 2466 children in Haryana revealed low sensitivity (6.9%) and positive predictive value (14.3%) of Mid-upper Arm Circumference (MUAC) at 115 mm cut-off for identifying Severe acute malnutrition (SAM). This raises concerns regarding the reliability of MUAC as a screening tool to identify SAM at the community-level.

متن کامل

Foot Length, Chest Circumference, and Mid Upper Arm Circumference Are Good Predictors of Low Birth Weight and Prematurity in Ethnic Minority Newborns in Vietnam: A Hospital-Based Observational Study

BACKGROUND The evaluation of tools to accurately identify low birth weight (LBW) and/or premature newborns in resource-limited countries is a research priority. We explored the use of foot length, chest circumference, and mid-upper arm circumference (MUAC) measured within 24 h as diagnostic tools for identifying newborns who are LBW, premature, or both; and compared measurements taken at birth ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015