The Evaluation of the Heat Loading from Steady, Transient and Off-normal Conditions in Aries Power Plants*
نویسندگان
چکیده
The heat loading on plasma facing components (PFCs) provides a critical limitation for design and operation of the first wall, divertor, and other special components. Power plants will have high power entering the scrape-off layer and transporting to the first wall and divertor. Although the design for steady heat loads is understood, the approach for transient and off-normal loading is not. The characterization of heat loads developed for ITER1 can be applied to power plants to better develop the operating space of viable solutions and point to research focus areas.
منابع مشابه
Developing off-design model of Yazd integrated solar combined cycle for analyzing environmental benefits of using solar energy instead of supplementary firing
An integrated solar combined cycle (ISCC) is analyzed at "off-design" operating conditions. Using the principles of thermodynamics heat and mass transfer a computer code is developed in FORTRAN programming language to simulate the system’s hourly performance under steady state conditions. Three scenarios are considered for the study. In the first one, only the combined cycle (CC) is studied. In...
متن کاملTransient thermal study of recuperative tube in tube heat exchanger operating in refrigeration system using experimental test and mathematical simulation
Joule-Thomson cooling systems are used in refrigeration and liquefaction processes. There are extensive studies on Joule-Thomson cryogenic systems, but most of them coverage steady state conditions or lack from experimental data. In the present work, transient thermal behavior of Joule-Thomson cooling system including counter current helically coiled tube in tube heat exchanger, expansion valve...
متن کاملAn experimental assessment of nanostructured materials embedded in a PCM-based heat sink for transient thermal management of electronic
In the present paper, an experimental assessment was performed on the transient thermal performance of a heat sink filled by a phase change material (PCM) and PCM embedded with carbon nanofibers (CNFs) and titania (TiO2) nanoparticles as nanostructured materials. In order to enhance the thermal conductivity of PCM, CNFs and TiO2 nanoparticles at different loadings (0.5wt. % and 2 wt.% of CNFs a...
متن کاملPower System Transient Stability Analysis Based on the Development and Evaluation Methods
A novel method to compute the stability region in power system transient stability analysis is presented. This method is based on the set analysis. The key to this method is to construct the Hamilton-Jacobi-Isaacs (HJI) partial differential equation (PDE) of a nonlinear system, using which we can compute the backward reachable set by applying the level set methods. The backward reachable set of...
متن کاملSafety Analysis of Spent Fuel Transportation Cask of Bushehr Nuclear Power Plant through the Passing of Fire Tunnel with ANSYS®10.0
The spent fuel assemblies (FAs) of Bushehr Nuclear Power Plant are planed to be transported by TK-13 casks. Each spent fuel transportation cask holds 12 spent FAs and has a thick steel container to provide shielding. The calculations have been performed for FAs with burn ups of 60 MWd/kg and a 3-years cooling period. The ANSYS®10.0 general finite element analysis package was se...
متن کامل