Reproducibility of Optovue RTVue Optical Coherence Tomography Retinal Thickness Measurements and Conversion to Equivalent Zeiss Stratus Metrics in Diabetic Macular Edema.
نویسندگان
چکیده
PURPOSE To evaluate the reproducibility of central subfield thickness (CST) and volume measurements from optical coherence tomography (OCT) images obtained with Zeiss Stratus and Optovue RTVue, and formulate equations to convert these measurements from RTVue to 'equivalent' Stratus values. METHODS Cross-sectional observational study from 309 eyes of 167 participants with diabetes and at least one eye with central-involved diabetic macular edema (DME; Stratus CST ≥ 250 μm) that underwent two replicate Stratus scans followed by two replicate RTVue scans centered on the fovea. RESULTS The Bland-Altman coefficient of repeatability for relative change in CST (the degree of change that could be expected from measurement variability) was not significantly different on Stratus and RTVue scans (10% and 16%, respectively). The replicate Stratus CST was within 10% of the initial Stratus measurement 93% of the time; the CST conversion equation predicted a Stratus value calculated from the observed RTVue value within 10% of the observed Stratus thickness 91% of the time. Bland-Altman limit of agreement for relative change in CST between measurements observed on different machines was 23%, comparing predicted versus actual Stratus measurement. CONCLUSIONS RTVue thickness reproducibility appears similar to Stratus. Conversion equations to transform RTVue measurements to Stratus-equivalent values within 10% of the observed Stratus RT are feasible. CST changes greater than 10% when using the same machine or 20% when switching from Stratus to RTVue, after conversion to Stratus equivalents, are likely due to a true change beyond measurement error. TRANSLATIONAL RELEVANCE Conversion equations to translate central retinal thickness measurements between OCT instruments is critical to clinical trials.
منابع مشابه
Comparison of spectral/Fourier domain optical coherence tomography instruments for assessment of normal macular thickness.
PURPOSE The purpose of this study was to report normal macular thickness measurements and assess reproducibility of retinal thickness measurements acquired by a time-domain optical coherence tomography (OCT) (Stratus, Carl Zeiss Meditec, Inc., Dublin, CA) and three commercially available spectral/Fourier domain OCT instruments (Cirrus HD-OCT, Carl Zeiss Meditec, Inc.; RTVue-100, Optovue, Inc., ...
متن کاملComparison of Spectral/Fourier Domain Optical Coherence Tomography Instruments for Assessment of Normal Macular Thickness Citation
PURPOSE—To report normal macular thickness measurements and assess reproducibility of retinal thickness measurements acquired by a time domain optical coherence tomography (OCT) (Stratus [Carl Zeiss Meditec, Inc., Dublin, CA, USA]) and three commercially available spectral / Fourier domain OCT instruments (Cirrus HD-OCT [Carl Zeiss Meditec, Inc., Dublin, CA, USA], RTVue-100 [Optovue, Inc., Frem...
متن کاملAssessment of artifacts and reproducibility across spectral- and time-domain optical coherence tomography devices.
PURPOSE To report the frequency of optical coherence tomography (OCT) scan artifacts and to compare macular thickness measurements, interscan reproducibility, and interdevice agreeability across 3 spectral-domain (SD) OCT (also known as Fourier domain; Cirrus HD-OCT, RTVue-100, and Topcon 3D-OCT 1000) devices and 1 time-domain (TD) OCT (Stratus OCT) device. DESIGN Prospective, noncomparative,...
متن کاملSCIENTIFIC REPORT Comparison of optical coherence tomography models OCT1 and Stratus OCT for macular retinal thickness measurement
Aims: To compare the values measured for retinal macular thickness with the first and last generations of the optical coherence tomograph (OCT1 and Stratus OCT, Zeiss, Humphrey Division). Methods: This was a cohort study. 59 eyes were examined: 17 had a normal macula and 42 had a diabetic macular oedema. In each eye, mean retinal thickness (RT) was measured automatically in the nine macular Ear...
متن کاملMacular thickness measurements in healthy eyes using six different optical coherence tomography instruments.
PURPOSE To compare central retinal thickness (CRT) measurements in healthy eyes by different commercially available OCT instruments and to compare the intersession reproducibility of such measurements. METHODS Six different OCT instruments (Stratus OCT [Carl Zeiss Meditec, Inc. Dublin, CA], SOCT Copernicus [Reichert/Optopol Technology, Inc., Depew, NY], Spectral OCT/SLO [Opko/OTI, Inc., Miami...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Translational vision science & technology
دوره 4 1 شماره
صفحات -
تاریخ انتشار 2015