Implantation of additional defibrillation lead into the coronary sinus: an effective method of decreasing defibrillation threshold.

نویسندگان

  • Rajmund Wilczek
  • Maciej Swiątkowski
  • Aleksandra Czepiel
  • Maciej Sterliński
  • Ewa Makowska
  • Piotr Kułakowski
چکیده

We report a case of successful implantation of an additional defibrillation lead into the coronary sinus due to high defibrillation threshold (DFT) in a seriously ill patient with a history of extensive myocardial infarction referred for implantable cardioverter- defibrillator implantation after an episode of unstable ventricular tachycardia. All previous attempts to reduce DFT, including subcutaneous electrode implantation, had been unsuccessful.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Prospective, Randomized Study

Background Recent development of a prototype singlelead unipolar transvenous defibrillator offers the possibility of device implantation with the ease of a permanent pacemaker. Lowering defibrillation energy requirements would allow for a further reduction in defibrillator generator size and enhance the feasibility of pacemaker-like placement. However, if achieving a lower defibrillation energy...

متن کامل

Additional coronary sinus shocking lead as rescue therapy after multiple internal and external defibrillation failures

High defibrillation threshold (DFT) and defibrillation failure can lead to intractable ventricular arrhythmias. Additional coronary sinus coil is an effective strategy to achieve marked reduction in DFT. However, physicians should retain this might prevent future coronary sinus lead placement in case the patient would develop complete left bundle branch block.

متن کامل

A permanent transvenous lead system for an implantable pacemaker cardioverter-defibrillator. Nonthoracotomy approach to implantation.

A transvenous lead system for implantable defibrillators would obviate a surgical thoracotomy and reduce the morbidity and mortality associated with implantation. We evaluated the clinical performance of a new nonthoracotomy lead system that included a defibrillation lead in the coronary sinus. At the time of defibrillator implantation, transvenous defibrillation leads were inserted percutaneou...

متن کامل

Transvenous defibrillation in humans via the coronary sinus.

A consistently effective transvenous defibrillation system for use in automatic defibrillators could significantly alter the approach to patients at risk of sudden death. Transvenous defibrillation systems that use a right ventricular (RV) electrode only or an RV electrode in combination with a chest patch are relatively inefficient at applying current to the posterolateral left ventricle. An R...

متن کامل

Electrode System Influence on Biphasic

Background. Several clinical studies have demonstrated a general superiority of biphasic waveform defibrillation compared with monophasic waveform defibrillation using epicardial lead systems. To test the breadth of utility of biphasic waveforms in humans, a prospective, randomized evaluation of defibrillation efficacy of monophasic and single capacitor biphasic waveform pulses was performed fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Kardiologia polska

دوره 69 12  شماره 

صفحات  -

تاریخ انتشار 2011