Acoustic Determination of Polymer Molecular Weights and Rotation Times
نویسندگان
چکیده
An acoustic waveguide device was shown to be sensitive to the molecular weight of poly(ethylene glycol) in solution over a molecular weight range determined by the operating frequency of the device. The acoustic device used generates a shear wave with displacement in the plane of the device surface and normal to the direction of propagation. Liquid over the device exhibits viscous coupling to the oscillating surface, affecting propagation of the acoustic wave. The propagation loss was shown to be directly proportional to the weight percentage of the solute. For a given weight percent of polymer in solution, the loss increased with increasing molecular weight until a maximum loss value was reached; this may be due to the fact that rotational times for polymer molecules increase with molecular weight until they reach a point at which the rotation is limited by the oscillation time on the device surface. The molecular weight at which the maximum loss value was attained was 10,000 g/mol for a device operating at 104 MHz and 3350 g/mol for a device operating at 331 MHz, implying a rotational time of 1 ns for each 2200 increase in molecular weight. © 2002 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys 40: 1490–1495, 2002
منابع مشابه
Quantification of Polyethylene Glycol Esters of Methotrexate and Determination of Their Partition Coefficients by Validated HPLC Methods
Conjugation of methotrexate (MTX) (MW 454) with different molecular weights of polyethylene glycol (PEG) including methoxy-peg (mpeg) 750 D and 5000 D and diol-peg 35000 D led to compounds that are physicochemically highly different from the parent compound, MTX. In this study, an HPLC system consisting of C8 column and UV detector (?=342 nm), using a mixture of 30:70 v/v phosphate-citrate buff...
متن کاملQuantification of Polyethylene Glycol Esters of Methotrexate and Determination of Their Partition Coefficients by Validated HPLC Methods
Conjugation of methotrexate (MTX) (MW 454) with different molecular weights of polyethylene glycol (PEG) including methoxy-peg (mpeg) 750 D and 5000 D and diol-peg 35000 D led to compounds that are physicochemically highly different from the parent compound, MTX. In this study, an HPLC system consisting of C8 column and UV detector (?=342 nm), using a mixture of 30:70 v/v phosphate-citrate buff...
متن کاملSYNTHESIS OF MOLECULARLY IMPRINTED POLYMER FOR DETERMINATION OF DILTIAZEM BY EXPERIMENTAL METHOD
Background & Aims: In this study, a magnetic molecular imprinted polymer was used to measure the diltiazem drug. Based on the structure and pharmaceutical agent group, methacrylic acid was selected as a monomer for Diltiazem. Ethylene glycol de-methacrylate and azobisisobutyronitrile were used as cross-linkers and polymerisation initiators, respectively. Also, chloroform was used as a porogenic...
متن کاملEffect of Polymer Grade and Plasticizer Molecular Weights on Viscoelastic Behavior of Coating Solutions
Film coating solutions containing different grades of HPMC (E5, E15 and E50) with and without polyethylene glycol (with various molecular weights) were examined by an oscillatory method, using Haake CV 100 rheometer. Fundamental rheological parameters (?, G? and G² ) were measured over the frequency range from 0.04 to 2 Hz. The variation with frequency of the loss tangent (a ratio of viscous to...
متن کاملEffect of Polymer Grade and Plasticizer Molecular Weights on Viscoelastic Behavior of Coating Solutions
Film coating solutions containing different grades of HPMC (E5, E15 and E50) with and without polyethylene glycol (with various molecular weights) were examined by an oscillatory method, using Haake CV 100 rheometer. Fundamental rheological parameters (?, G? and G² ) were measured over the frequency range from 0.04 to 2 Hz. The variation with frequency of the loss tangent (a ratio of viscous to...
متن کامل