Actual vs optimal fetal hematocrit measured with punctures of cord blood in utero: Relationship with umbilical artery resistance.

نویسندگان

  • Jean-Frédéric Brun
  • Pierre Boulot
  • Emmanuelle Varlet-Marie
چکیده

Physiological studies on fetal blood in narrow glass tubes have suggested that fetal optimal hematocrit (hct) might be as high as 60%. A theoretical 'ideal' hct can also be predicted with a theoretical curve of hematocrit/viscosity (h/η) ratio vs hct constructed with Quemada's model. We used the database of one of our previous papers on fetal hemorheology to reinterpret its results with this concept. A series of 28 intrauterine cord punctures (between 19 and 33 weeks gestation) with doppler measurements of resistance in umbilical arteries was studied. The theoretical 'optimal hematocrit' was well correlated to actual (r = 0.857, p < 0.01) but systematically lower (Bland-Altman plot +12.1[8.52-15.7]) than the actual one. Umbilical artery resistance index is correlated with actual hematocrit (r = 0.407, p < 0.05), the discrepancy between ideal and actual (r = - 0.542, p < 0.05) but not predicted ideal hematocrit, suggesting that the discrepancy between ideal and actual may reflect an adaptative decrease aiming at reducing vascular resistance. These findings indicate that prediction of ideal hematocrit with Quemada's equation makes sense in fetal blood, and suggest that a 'viscoregulatory mechanism' maintains hematocrit below this theoretical value in order to avoid excess vascular resistance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Maternal Serum and Umbilical Cord Blood Leptin Level in IUGR Neonates

Background: Gestational weight gain is an impressive factor in the fetal outcome. Intrauterine growth restriction (IUGR) is one of the most important problems during fetal period that may lead to many perinatal and long-term complications and growing neonatal morbidities and mortalities. The aim of the study was to ascertain the relationship between umbilical cord blood leptin concentration and...

متن کامل

Evaluation of the correlation between fetal well being tests with APGAR score and PH of umbilical artery in high risk pregnant women

Introduction: Acidosis-hypoxic phenomenon is a valid indicator to determine fetal distress and is defined by measuring the blood pH of umblical cord. None of the present screening tests for evaluation of pregnant mothers have acceptable clinical accuracy to assess fetal acidosis. We decided to evaluate the relationship between fetal well being tests Non-Stress Test (NST), Oxytocin Challenge T...

متن کامل

Evaluation of the correlation between fetal well being tests with APGAR score and PH of umbilical artery in high risk pregnant women

Introduction: Acidosis-hypoxic phenomenon is a valid indicator to determine fetal distress and is defined by measuring the blood pH of umblical cord. None of the present screening tests for evaluation of pregnant mothers have acceptable clinical accuracy to assess fetal acidosis. We decided to evaluate the relationship between fetal well being tests Non-Stress Test (NST), Oxytocin Challenge Tes...

متن کامل

The Correlation between Type of Delivery and Umbilical Cord Blood Hemoglobin and Hematocrit in Full- Term Neonates

Introduction: Neonates with lower hemoglobin and Hematocrit are more at risk of iron deficiency anemia. This rate is influenced by several factors. Children's health can be improved by identifying these factors and taking appropriate actions. This study determined the relationship between type of delivery and umbilical cord blood hemoglobin and Hematocrit. Methods: This descriptive correlation...

متن کامل

Correlation between Lead in Maternal Blood, Umbilical Cord Blood, and Breast Milk with Newborn Anthro-pometric Characteristics

Background: Breast milk can be a source of toxic material, along with the transfer of nutrients needed for infant growth. This study was conducted to measure the level of lead in maternal and neonatal blood and breast milk in Tehran, Iran.Methods: In this cross-sectional study, 150 mothers and their infants were studied. Samples of maternal blood, fetal umbilical cord blood, breast milk, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical hemorheology and microcirculation

دوره 64 4  شماره 

صفحات  -

تاریخ انتشار 2016