Filtration via Conventional Glass Fiber Filters in 15N2 Tracer Assays Fails to Capture All Nitrogen-Fixing Prokaryotes
نویسندگان
چکیده
Biological dinitrogen fixation (BNF) represents a major input of reduced nitrogen (N) to the oceans. Accurate direct measurements of BNF rates are crucial for reliably determining the biogeochemical significance of diazotrophy at local and global scales. Traditionally, borosilicate glass fiber filters (GF/F, Whatman) with a nominal pore size of 0.7μm are used to collect suspended particles by filtration after incubations with added N2 tracer. We carried out BNF experiments in the Baltic Sea, Danish coastal waters, and the Pacific Ocean comparing the retentive characteristics of precombusted GF/F filters with newer Advantec glass fiber filters which have a smaller nominal pore size of 0.3μm. Where BNF was detected, rates were nearly always higher, and sometimes even exclusively detectable, when using Advantec filters. In the majority of samples across tested habitats, significantly more cells were lost to GF/F filtrate (average = 51%, range = 10–70% of cells) than to Advantec filtrate (average = 40%, range = 10– 54%). Using Illumina sequencing of nitrogenase (nifH) gene amplicons, we show that diazotroph communities can markedly differ between bulk water and filtrates from GF/F and Advantec filtrations, suggesting that different diazotrophs can pass through the filter types. In order to reduce the potential underestimations of BNF due to filtration loss of diazotrophs, we recommend using Advantec filters or alternatively silver membranes with 0.2μm pore size, especially in waters expected to be inhabited by relatively small, unicellular diazotrophs.
منابع مشابه
The Impact of Fiber Dispersion on Filtration and Tensile Properties of Glass Fiber Filter Paper
Air quality control has become increasingly important in many industrial areas. Glass fiber filter paper is widely used for the collection of airborne particulate matter. Since glass fiber is fragile, fiber dispersion is believed to be important for controlling filter paper properties. In this paper, the impact of fiber dispersion on filtration performance and tensile properties was studied. Tw...
متن کاملPreparation and characterization of polyethylene/ glass fiber composite membrane prepared via thermally induced phase separation method
Grinded glass fiber (GGF) embedded high density polyethylene (HDPE) membranes were prepared via thermally induced phase separation method. FESEM images showed that all the membranes had leafy structure, indicating a solid-liquid mechanism during phase separation. The results of EDX and TGA analyses confirmed that the fibers were dispersed in the HDPE matrix uniformly. Normalized water flux of t...
متن کاملThe Contamination of Commercial 15N2 Gas Stocks with 15N–Labeled Nitrate and Ammonium and Consequences for Nitrogen Fixation Measurements
We report on the contamination of commercial 15-nitrogen (15N) N2 gas stocks with 15N-enriched ammonium, nitrate and/or nitrite, and nitrous oxide. 15N2 gas is used to estimate N2 fixation rates from incubations of environmental samples by monitoring the incorporation of isotopically labeled 15N2 into organic matter. However, the microbial assimilation of bioavailable 15N-labeled N2 gas contami...
متن کاملEvaluation of Glass Fiber Hepa Filters as a Function of Media Velocity
The Department of Energy currently employs high-efficiency particulate air (HEPA) filters in a variety of applications, such as particulate matter removal from ventilation air and treatment of off-gasses from storage or remediation of mixed wastes. Section FC of the ASME AG-1 Code addresses glass fiber HEPA filters and restricts the media velocity to a maximum of 5 ft/min. Advances in filtratio...
متن کاملEffect of Filter Inhomogeneity on Deep-Bed Filtration Process – A CFD Investigation
Aerosol filtration in fibrous filters is one of the principal methods of removal of solid particles from the gas stream. The classical theory of depth filtration is based on the assumption of existing single fiber efficiency, which may be used to the recalculation of the overall efficiency of the entire filter. There are several reasons for inappropriate estimation of the single fi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2018