X-ray beam stabilization at BL-17A, the protein microcrystallography beamline of the Photon Factory

نویسندگان

  • Noriyuki Igarashi
  • Kazuyuki Ikuta
  • Toshinobu Miyoshi
  • Naohiro Matsugaki
  • Yusuke Yamada
  • Mohammad S. Yousef
  • Soichi Wakatsuki
چکیده

BL-17A is a new structural biology beamline at the Photon Factory, Japan. The high-brilliance beam, derived from the new short-gap undulator (SGU#17), allows for unique protein crystallographic experiments such as data collection from microcrystals and structural determination using softer X-rays. However, microcrystal experiments require robust beam stability during data collection and minor fluctuations could not be ignored. Initially, significant beam instability was observed at BL-17A. The causes of the beam instability were investigated and its various sources identified. Subsequently, several effective countermeasures have been implemented, and the fluctuation of the beam intensity successfully suppressed to within 1%. Here the instability reduction techniques used at BL-17A are presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvements toward highly accurate diffraction experiments at the macromolecular micro-crystallography beamline BL-17A

BL-17A is a macromolecular crystallography beamline dedicated to diffraction experiments conducted using micro-crystals and structure determination studies using a lower energy X-ray beam. In these experiments, highly accurate diffraction intensity measurements are definitively important. Since this beamline was constructed, the beamline apparatus has been improved in several ways to enable the...

متن کامل

Improvement of an automated protein crystal exchange system PAM for high-throughput data collection

Photon Factory Automated Mounting system (PAM) protein crystal exchange systems are available at the following Photon Factory macromolecular beamlines: BL-1A, BL-5A, BL-17A, AR-NW12A and AR-NE3A. The beamline AR-NE3A has been constructed for high-throughput macromolecular crystallography and is dedicated to structure-based drug design. The PAM liquid-nitrogen Dewar can store a maximum of three ...

متن کامل

A New XAFS Beamline NW10A at the Photon Factory

A new XAFS beamline NW10A using bending magnet radiation from 6.5 GeV PF-AR has been constructed. NW10A consists of a Si(311) double crystal monochromator and a Pt-coated bent cylindrical focusing mirror and provides focused X-ray beam between 8 and 42 keV. The obtained flux through a 1mm square slit is 1×10 ph/s at 20 keV and 7×10 ph/s at 30keV, which are 20 and 200 times more intense than obt...

متن کامل

High-throughput operation of sample-exchange robots with double tongs at the Photon Factory beamlines

Sample-exchange robots that can exchange cryo-pins bearing protein crystals out of experimental hutches according to user instructions have been developed. The robots were designed based on the SAM (Stanford Synchrotron Research Laboratory automated mounting) system. In order to reduce the time required for the sample exchange, the single tongs of the SAM system were modified and a double-tongs...

متن کامل

A Second Beam-diagnostic Beamline for the Advanced Light Source*

A second beamline, BL 7.2, completely dedicated to beam diagnostics is being installed at the Advanced Light Source (ALS). The design has been optimized for the measurement of the momentum spread and emittance of the stored beam in combination with the existing diagnostic beamline, BL 3.1. A detailed analysis of the experimental error has allowed the definition of the system parameters. The obt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Synchrotron Radiation

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2008