The implant-supported telescopic prosthesis: a biomechanical analysis.
نویسندگان
چکیده
This in vitro project investigated load transfer through screw-retained telescopic prostheses. Three Brånemark System implants incorporating strain gauges were embedded in an aluminum block. Telescopic prostheses that included 1 mesial and 1 distal cantilever were fabricated over 1 central EsthetiCone and 2 Ti-Adapt abutments. The buffering capacity of the cement in a combined screw-retained/cemented prosthesis was studied. The degree of misfit of the prostheses could be adjusted by applying shims of various thicknesses under the EsthetiCone. Load distribution was measured while a 50-N load was applied in turn over each implant and each cantilever. The results showed that tightening the central prosthetic screw widened the load distribution. The cement accommodated misfits between the layers of the telescope, significantly reducing bending moments on some supporting implants. The system exhibited a degree of tolerance to misfit and can provide a versatile prosthodontic option.
منابع مشابه
مطالعه تنشهای اطراف ایمپلنت به روش اجزای محدود در بریجهای با ساپورت دندان/ایمپلنت در شرایط اتصال سخت و غیرسخت در پروتزهای سمان شونده
Background and Aims: Freestanding fixed partial prosthesis is considered the first choice whenever possible. However, anatomical limitations for implants and other reasons may create situation in which it would be preferable to connect the implants to teeth. A biomechanical dilemma in a tooth/implant-supported system comes from dissimilar mobility. This disparity cause the bridge to function as...
متن کاملMaintenance Requirements of Screw- Retained Implant Prosthesis versus Telescopic Overdenture: A Randomized Controlled Trial
Statement of problem: There is little information about the maintenance requirements of implant restorations. Purpose: To compare the prosthodontic maintenance requirements of screw-retained implant prosthesis versus that of telescopic overdentures after an observation period of 18 months. Materials and methods: 26 completely edentulous patients were enrolled in the study. Patients were divided...
متن کاملEvaluating the Frequency of Implant-Supported Fixed Prosthesis Complications in Yazd Dental School in 2020
Introduction: Evaluating the frequency of complications in implant supported prosthesis such as screw loosening and porcelain fracture is important for prevention and management of these problems. The purpose of this study was to evaluate the frequency of implant-supported fixed prosthesis complications in Yazd dental school in 2020. Methods: In this descriptive cross-sectional study, the pat...
متن کاملTelescopic Overdenture and Implant Supported Fixed Partial Denture: A Pragmatic Treatment Approach
This case report presents a patient who had been rehabilitated with a telescopic overdenture and implant supported fixed partial denture (ISFPD). The treatment process was as follows: (1) fabricating telescopic crowns and overdenture prosthesis for the lower jaw and a temporary complete denture for the upper jaw, (2) using the temporary denture as diagnostic and surgical guide to optimize denta...
متن کاملCement- and screw-retained implant-supported prostheses: up to 10 years of follow-up of a new design.
PURPOSE This retrospective study investigated treatment outcomes over 10 years of a new prosthesis design in implant prosthodontics that uses a combined cement- and screw-retained principle. MATERIALS AND METHODS The clinical data of 78 implant-supported prostheses were examined. Each prosthesis incorporated at least 1 screw-retained element and 1 or more cement-retained telescopic units. One...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The International journal of oral & maxillofacial implants
دوره 16 1 شماره
صفحات -
تاریخ انتشار 2001