Estimation of local confidence limit for 6 MV photon beam IMRT system using AAPM TG 119 test protocol
نویسندگان
چکیده
1Department of Radiation Oncology, SevenHills Hospital, Mumbai, India 2Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, India Received October 17, 2015; Revised January 02, 2016; Accepted January 16, 2016; Published Online February 03, 2016 Original Article Abstract Purpose: The aim of this study was to estimate local confidence limit for 6 MV photon beam based intensity modulated radiation therapy (IMRT) using TG119 test protocol. Methods: The American Association of Physicists in Medicine (AAPM) Task Group 119 (TG119) prescribed a protocol to evaluate overall accuracy of IMRT system rather than independent uncertainty in dose calculation, dose delivery and measurement system. Two preliminary and five clinical test cases were created based on dose prescriptions and planning objectives given by TG119 report. Verification plans were created in a planning slab phantom, 2D Matrix dosimetry system (I’MatriXX) with multicube phantom and aS-1000 electronic portal imaging device (EPID). Radiation absorbed doses to high dose points in the planning target volume (PTV) region and low dose points in avoidance structures were measured using CC13 ionization chamber having sensitive volume of 0.13 cm3. The measured and planned doses were normalized with respect to their prescription doses and intercompared. The gamma analysis was carried out for both I’MatriXX and EPID, adopting the acceptance criteria of 3% DD (dose difference) and 3 mm DTA (distance to agreement) with 10% threshold dose. Results: For the point dose measurements with ion chamber, the average dose difference ratio in high dose low gradient PTV region was -0.0133 ± 0.012 corresponding to a confidence limit of 0.037. The average dose difference in low dose region (avoidance structure) was -0.00004 ± 0.010 corresponding to a confidence limit of 0.021. The average percentage of points passing the gamma criteria of 3% DD and 3 mm DTA for composite planar dose distribution measured by I’MatriXX was 99.47 ± 0.43 which corresponds to a confidence limit of 1.38 (i.e. 98.62% passing). Similarly, the average percentage of points passing the gamma criteria of 3% DD and 3 mm DTA for per-field dose distribution measured by EPID was 98.00 ± 2.49 which corresponds to a confidence limit of 6.87. Conclusion: Our results were well within action level given by AAPM TG119 report through multi-institutional study providing us adequate confidence in delivering IMRT treatment.
منابع مشابه
Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملApplication of AAPM TG 119 to volumetric arc therapy (VMAT)
The purpose of this study was to create AAPM TG 119 benchmark plans for volumetric arc therapy (VMAT) and to compare VMAT plans with IMRT plan data. AAPM TG 119 proposes a set of test clinical cases for testing the accuracy of IMRT planning and delivery system. For these test cases, we generated two treatment plans, the first plan using 7-9 static dMLC IMRT fields and a second plan utilizing on...
متن کاملThe effect of high energy photon beam in dose- volume parameters and integral dose of normal structures in Head and neck IMRT
Introduction: The aim of this study is to investigate the effect of partially used high photon energies on dosimetric parameters and integral doses of nasopharynx IMRT plans. Materials and Methods: Two 7 coplanar IMRT plan were created for eleven patients (6 MV only IMRT plan in both phase1 and phase2 and 6 MV phase1-mixed energies (6 MV and 15 MV) phase2...
متن کاملDosimetric Validation of Volumetric Modulated Arc Therapy (VMAT) Using AAPM TG-119 Benchmark Plans in an Upgraded CLINAC 2100CD for Flattening Filter Free (FFF) Photon Beams
Background: Recently we have upgraded our Varian Clinac 2100CD with a 6MV FFF beam, this upgrade being the first of its kind in our country. Even though the dosimetric characteristics of FFF beams have been reported both in experimental and Monte Carlo studies, application in planning and delivery is complex. The aim of this study was to validate the commissioning of upgraded FFF beams dosimetr...
متن کاملComparison of AAPM Addendum to TG‐51, IAEA TRS‐398, and JSMP 12: Calibration of photon beams in water
The American Association of Physicists in Medicine (AAPM) Working Group on TG-51 published an Addendum to the AAPM's TG-51 protocol (Addendum to TG-51) in 2014, and the Japan Society of Medical Physics (JSMP) published a new dosimetry protocol JSMP 12 in 2012. In this study, we compared the absorbed dose to water determined at the reference depth for high-energy photon beams following the recom...