Pulse subtraction Doppler
نویسندگان
چکیده
Recent advances have demonstrated the feasibility of molecular imaging using targeted microbubbles and ultrasound. One technical challenge is to selectively detect attached bubbles from those freely flowing bubbles and surrounding tissue. Pulse Inversion Doppler is an imaging technique enabling the selective detection of both static and moving ultrasound contrast agents: linear scatterers generate a single band Doppler spectrum, while non-linear scatterers generate a double band spectrum, one being uniquely correlated with the presence of contrast agents and non-linear tissue signals. We demonstrate that similar spectrums, and thus the same discrimination, can be obtained through a Doppler implementation of Pulse Subtraction. This is achieved by reconstructing a virtual echo using the echo generated from a short pulse transmission. Moreover by subtracting from this virtual echo the one generated from a longer pulse transmission, it is possible to fully suppress the echo from linear scatterers, while for non-linear scatterers, a signal will remain, allowing classical agent detection. Simulations of a single moving microbubble and a moving linear scatterer subject to these pulses show that when the virtual echo and the long pulse echo are used to perform pulsed Doppler, the power Doppler spectrum allows separation of linear and non-linear moving scattering. Similar results are obtained on experimental data acquired on a flow containing either microbubble contrast agents or linear blood mimicking fluid. This new Doppler method constitutes an alternative to Pulse Inversion Doppler and preliminary results suggest that similar dual band spectrums could be obtained by the combination of any non-linear detection technique with Doppler demodulation. PAC’: 8763 dk
منابع مشابه
Pulse Doppler Analysis in External Ophthalmic and the Long Ciliary Ophthalmic Arteries in the Cat
Objective- Analysis of the PSV (peak systolic velocity), EDV (end diastolic velocity) and RI (Resistant Index) in external ophthalmic and the long ciliary ophthalmic arteries in the cat by pulse Doppler. Design- Descriptive study Animals- 12 short haired “Tomcats” weighted about 3.9± 0.9 Kg no e general and optic disease in clinical, paraclinical and ophthalmoscopic examinations. Pr...
متن کاملAnalysis of human pulse performance using the device of laser Doppler vibrometer
This article has no abstract.
متن کاملDigital subtraction angiography in patients with cerebral ischaemic attacks and normal continuous wave doppler studies.
The cervico-cranial arteries were studied using digital subtraction angiography in 50 patients with reversible cerebral ischaemic attacks and normal continuous wave Doppler examination. Digital subtraction angiography was able to visualise the arteries satisfactorily in 45 patients (90%), and revealed minor arterial abnormalities in 12 patients (24%). However, neither occlusions nor stenoses gr...
متن کاملAssessment of Weighting Functions Used in Oppermann Codes in Polyphase Pulse Compression Radars
Polyphase is a common class of pulse compression waveforms in the radar systems. Oppermann code is one of the used codes with polyphone pattern. After compression, this code has little tolerant against Doppler shift in addition to its high side lobe level. This indicates that the use of Oppermann code is an unsuitable scheme to radars applications. This paper shows that the use of amplitude wei...
متن کاملارزیابی و بررسی نتایج حاصل از داپلر فراصوتی در مقایسه با آنژیوگرافی تفریقی دیجیتال در تشخیص تنگ شدگیهای شریان کاروتید داخلی
Introduction: Digital Subtraction Angiography (DSA) is the standard method for detection of carotid artery stenosis. This technique has high radiation dose. With the progress of imaging techniques, noninvasive or minimally invasive methods like the CT angiography, MR angiography and ultrasonography with Doppler or Duplex mode were applicable. This study aimed to evaluate and assesse the results...
متن کامل