High-throughput Toroidal Grating Beamline for Photoelectron Spectroscopy at CAMD.

نویسندگان

  • O Kizilkaya
  • R W Jiles
  • M C Patterson
  • C A Thibodeaux
  • E D Poliakoff
  • P T Sprunger
  • R L Kurtz
  • E Morikawa
چکیده

A 5 meter toroidal grating (5m-TGM) beamline has been commissioned to deliver 28 mrad of bending magnet radiation to an ultrahigh vacuum endstation chamber to facilitate angle resolved photoelectron spectroscopy. The 5m-TGM beamline is equipped with Au-coated gratings with 300, 600 and 1200 lines/mm providing monochromatized synchrotron radiation in the energy ranges 25-70 eV, 50-120 eV and 100-240 eV, respectively. The beamline delivers excellent flux (~1014-1017 photons/sec/100mA) and a combined energy resolution of 189 meV for the beamline (at 1.0 mm slit opening) and HA-50 hemispherical analyzer was obtained at the Fermi level of polycrystalline gold crystal. Our preliminary photoelectron spectroscopy results of phenol adsorption on TiO2 (110) surface reveals the metal ion (Ti) oxidation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of the 3 m TGM beamline, at CAMD, for constant initial state spectroscopy

The 3 m toroidal grating monochromator (TGM) VUV beamline at CAMD/LSU was realigned to achieve better illumination of the monochromator gratings with the goal of substantially increasing the fl ux at the higher photon energies. This is partly accomplished through a tilting of the monochromator (by about of 13.5°), with respect to the plane defi ned by the synchrotron, providing a smaller grazin...

متن کامل

Upgraded varied-line-space PGM beamline at CAMD

The Center for Advanced Microstructures and Devices’(CAMD) aging plane-grating soft x-ray monochromator beamline was upgraded to a varied-line-space plane-grating monochromator (VLSPGM) beamline. Preliminary measurements indicate significant performance improvements in both the resolving power and the throughput over its predecessor. However, it was found that the VLSPGM has less than the calcu...

متن کامل

Photoelectron spectroscopy study on Li substituted NiO using PES beamline installed on Indus-1

Photoelectron spectroscopy beamline based on a toroidal grating monochromator (TGM) is recently commissioned on Indus-1 storage ring. It has been used to carry out valence band photoemission study of Li substituted NiO. In this paper initially a brief description of the beamline components and the experimental station for angle integrated photoemission experiment is presented. The later part of...

متن کامل

The Development of the GCPCC Protein Crystallography Beamline at CAMD

The Gulf Coast Protein Crystallography Consortium (GCPCC) is developing a beamline at the LSU/CAMD synchrotron. This beamline will be capable of standard macromolecular multiple-wavelength anomalous diffraction (MAD) phasing experiments over an energy range of 7-17.5 keV. The optical configuration uses a vertical collimating mirror, a channel-cut Si (111) monochromator and a focusing toroidal m...

متن کامل

KMC-1: a high resolution and high flux soft x-ray beamline at BESSY.

The crystal monochromator beamline KMC-1 at a BESSY II bending magnet covers the energy range from soft (1.7 keV) to hard x-rays (12 keV) employing the (n,-n) double crystal arrangement with constant beam offset. The monochromator is equipped with three sets of crystals, InSb, Si (111), and Si (422) which are exchangeable in situ within a few minutes. Beamline and monochromator have been optimi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of physics. Conference series

دوره 493  شماره 

صفحات  -

تاریخ انتشار 2014