Dosimetry and mechanical accuracy of the first rotating gamma system installed in North America.
نویسندگان
چکیده
The purpose of this paper is to present the dosimetry and mechanical accuracy of the first rotating gamma system (RGS) installed in North America for stereotactic radiosurgery. The data were obtained during the installation, acceptance test procedure, and commissioning of the unit. The RGS unit installed at UC Davis Cancer Center (RGSu) has modifications on the source and collimator bodies from the earlier version of the Chinese RGS (RGSc). The differences between these two RGSs are presented. The absolute dose at the focal point was measured in a 16-cm-diam acrylic phantom using a small volume chamber, which was calibrated at the University of Wisconsin Accredited Dosimetry Calibration Laboratory (UW-ADCL). The dose in acrylic was then converted to a dose in water. A collimator output factor from each of the four different collimator sizes ranging from 4, 8, 14, and 18 mm was measured with (1) a smaller volume chamber and (2) approximately 3.0 mm x 3.0 mm x 1.0 mm TLD chips in the same acrylic phantom. The Gafchromic films were used for the dose profile, collimator output factor, and mechanical/radiation field isocentricity measurements. The TLD chips were processed in-house whereas Gafchromic films were processed both at the UW-ADCL and in-house. The timer error, timer accuracy, and timer linearity were also determined. The dose profiles were found to be similar between RGSc and RGSu. The 4 mm collimator output factor of the RGSu was approximately 0.6, similar to that from RGSc, in comparison to 0.8 in the report for a Leksell Model U Gamma-Knife. The mechanical/radiation field isocentricity for RGSc and RGSu is found to be similar and is within 0.3 mm in both X and Y directions. In the Z direction, the beam center of the RGSu is shifted toward the sources by 0.75 mm from the mechanical isocenter whereas no data are available for RGSc. Little dosimetric difference is found between RGSu and RGSc. It is reported that RGSc has the same dosimetric and mechanical characteristics as the Model U Gamma-Knife. Therefore, RGSu should be capable of achieving stereotactic radiosurgery with the same degree of dosimetric and mechanical accuracy as with the Gamma-Knife.
منابع مشابه
Development of A Head Docking Device for Linac-based Stereotactic Radiosurgery System to be Installed on Neptun 10 PC Linac
Introduction: Stereotactic radiosurgery is a technique for the treatment of intracranial lesions with highly collimated x-ray beam. Linac-based radiosurgery is currently performed by two techniques: couch or pedestal mounted. In the first technique, a device is required to affix patient's head to a couch and moreover to translate it accurately. Structure of suc...
متن کاملMonte Carlo Evaluation of Gamma Knife Dose Profile in Real Brain Phantom
Introduction The Gamma Knife system is designed solely for non-invasive treatment of brain disorders, and it benefits from stereotactic surgical techniques. Dose calculations required in the system are performed by GammaPlan code; in this code, brain tissue is considered uniform. In the present study, we evaluated the effect of Gamma Knife system on the obtained dose through simulating a real ...
متن کاملEffect of Surface Energy on the Vibration Analysis of Rotating Nanobeam
In this study, the free vibration behavior of rotating nanobeam is studied. Surface effects on the vibration frequencies of nanobeam are considered. To incorporate surface effects, Gurtin–Murdoch model is proposed to satisfy the surface balance equations of the continuum surface elasticity. Differential quadrature method is employed and in order to establish the accuracy and applicability of t...
متن کاملA Novel Intelligent Fault Diagnosis Approach for Critical Rotating Machinery in the Time-frequency Domain
The rotating machinery is a common class of machinery in the industry. The root cause of faults in the rotating machinery is often faulty rolling element bearings. This paper presents a novel technique using artificial neural network learning for automated diagnosis of localized faults in rolling element bearings. The inputs of this technique are a number of features (harmmean and median), whic...
متن کاملEvaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT
Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 29 11 شماره
صفحات -
تاریخ انتشار 2002