Diagnostic accuracy of noncontrast MRI for detection of glenohumeral cartilage lesions: a prospective comparison to arthroscopy.

نویسندگان

  • Corinne VanBeek
  • Bryan J Loeffler
  • Alexa Narzikul
  • Victoria Gordon
  • Michael J Rasiej
  • Jonathan K Kazam
  • Joseph A Abboud
چکیده

BACKGROUND The purpose of this study was to determine the prevalence of glenohumeral articular cartilage lesions in patients with rotator cuff tendinopathy and to assess the accuracy of noncontrast magnetic resonance imaging (MRI) in detecting these defects compared with the "gold standard" of arthroscopy. METHODS Noncontrast MRI studies obtained in 84 consecutive patients undergoing shoulder arthroscopy for rotator cuff tendinopathy (mean age, 54.8 years; range, 17-82 years) were prospectively evaluated for glenohumeral cartilage lesions. Two fellowship-trained, experienced musculoskeletal radiologists were blinded from the arthroscopic findings and independently evaluated the glenoid and humeral head cartilage on 2 separate occasions. RESULTS At arthroscopy, cartilage lesions of the humeral head were detected in 23 patients (frequency, 27.4%), and glenoid cartilage lesions were found in 20 patients (frequency, 23.8%). For detection of a humeral lesion on MRI, the radiologists' combined accuracy was 78%, sensitivity was 43%, and specificity was 91%. The combined accuracy for detection of glenoid lesions on MRI was 84%, sensitivity was 53%, and specificity was 93%. Combining the readers, low-grade lesions (International Cartilage Repair Society grades 1 and 2) of the glenoid and humerus were read as negative on MRI in 63% and 86% of cases, respectively. CONCLUSION Overall accuracy of noncontrast MRI for detection of glenohumeral articular cartilage lesions is good; however, interpretation is reader dependent, and accuracy is significantly reduced for detection of low-grade lesions. On the basis of these findings, we recommend that patients with rotator cuff tendinopathy undergoing arthroscopy be informed that the presence and severity of cartilage lesions may be underestimated on MRI.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of MRI in Comparison with Arthroscopic Findings in the Diagnosis of Anterior Cruciate Ligament and Meniscus Tears

Background: Magnetic resonance imaging (MRI) is of great aid in the diagnosis of knee lesions. Nevertheless, arthroscopy has remained the reference standard for the diagnosis of internal derangements of the knee, against which alternative diagnostic modalities should be compared. This study was designed to assess the value of MRI and clinical examination in the diagnosis of Anterior Cruciate Li...

متن کامل

MRI efficacy in diagnosing internal lesions of the knee: a retrospective analysis

BACKGROUND Many surgeons tend to believe that MRI is an accurate, non invasive diagnostic method, enough to lead to decisions for conservative treatment and save a patient from unnecessary arthroscopy. We conducted a retrospective study to investigate the accuracy of the MRI of the knee for the detection of injuries of the meniscus, cruciate ligaments and articular cartilage, in comparison with...

متن کامل

Diagnostic accuracy in detecting tears in the proximal biceps tendon using standard nonenhancing shoulder MRI

BACKGROUND There is a paucity of data in the literature evaluating the performance of noncontrast MRI in the diagnosis of partial and complete tears of the proximal portion of the long head of the biceps (LHB) tendon. The objective of this study was to evaluate the accuracy of noncontrast magnetic resonance imaging (MRI) compared to arthroscopy for the diagnosis of pathology involving the intra...

متن کامل

One Screening Magnetic Resonance Imaging Sequence in Evaluation of Chondral and Meniscal Lesions of the Knee − A Pilot Study

This prospective study aimed to evaluate if chondral and meniscal lesions in symptomatic knees of osteoarthritis patients can be reliably identified using only one sagittal dual-echo MRI (Magnetic Resonance Imaging) sequence. MRI was performed on 13 patients after knee arthroscopy due to knee pain and clinically suspected osteoarthritis using a 1.5-Tesla scanner with knee coil and a sagittal du...

متن کامل

Accuracy of cartilage-specific 3-Tesla 3D-DESS magnetic resonance imaging in the diagnosis of chondral lesions: comparison with knee arthroscopy.

BACKGROUND Arthroscopy is considered as "the gold standard" for the diagnosis of traumatic intraarticular knee lesions. However, recent developments in magnetic resonance imaging (MRI) now offer good opportunities for the indirect assessment of the integrity and structural changes of the knee articular cartilage. The study was to investigate whether cartilage-specific sequences on a 3-Tesla MRI...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of shoulder and elbow surgery

دوره 23 7  شماره 

صفحات  -