Functional dependence of cancellous bone shear properties on trabecular microstructure evaluated using time-lapsed micro-computed tomographic imaging and torsion testing.
نویسندگان
چکیده
When compressed axially, cancellous bone often fails at an oblique angle along well-defined bands, highlighting the importance of cancellous bone shear properties. Torsion testing to determine shear properties of cancellous bone has often been conducted under conditions appropriate only for axisymmetric specimens comprised of homogeneous and isotropic materials. However, most cancellous bone specimens do not meet these stringent test conditions. Therefore, we studied the application of the stepwise torsion testing system in biologic specimens with viscoelastic behavior. We explore the functional dependence of cancellous bone shear properties on trabecular microstructure and its spatial distribution, specifically the contribution of the subregion with the minimum polar moment of inertia to the overall failure properties. Torsional properties of whale trabecular specimens obtained by the incremental application of stepwise torque were not different from those obtained via continuous testing. Average polar moment of inertia accounted for 82 and 67% of the variation in shear modulus and shear stress, respectively. However, torsional properties were better predicted by the subregion with minimum polar moment of inertia, describing 87 and 74% of the variation in shear modulus and shear stress. The use of a novel torsion testing system for nonhomogeneous, orthotropic cancellous bone using stepwise application of torsion and simultaneous micro-computed tomographic imaging was further studied. Most importantly, a heterogeneous cancellous bone microstructural environment, the subregion with the minimum polar moment of inertia, hence the weakest spatial distribution of bone, predicted the shear properties for the entire bone volume.
منابع مشابه
Human cancellous bone from T12-L1 vertebrae has unique microstructural and trabecular shear stress properties.
Increase of trabecular stress variability with loss of bone mass has been implicated as a mechanism for increased cancellous bone fragility with age and disease. In the current study, a previous observation that trabecular shear stress estimates vary along the human spine such that the cancellous tissue from the thoracic 12 (T12)-lumbar 1 (L1) junction experiences the highest trabecular stresse...
متن کاملAssessment of the Impact of Zoledronic Acid on Ovariectomized Osteoporosis Model Using Micro-CT Scanning
PURPOSE/OBJECTIVE Prompted by preliminary findings, this study was conducted to investigate the impact of zoledronic acid on the cancellous bone microstructure and its effect on the level of β-catenin in a mouse model of postmenopausal osteoporosis. METHODS AND MATERIALS 96 8-week-old specific-pathogen-free C57BL/6 mice were randomly divided into 4 groups (24 per group): a sham group, an ovar...
متن کاملEffect of micro-computed tomography voxel size and segmentation method on trabecular bone microstructure measures in mice
Micro-computed tomography (μCT) is currently the gold standard for determining trabecular bone microstructure in small animal models. Numerous parameters associated with scanning and evaluation of μCT scans can strongly affect morphologic results obtained from bone samples. However, the effect of these parameters on specific trabecular bone outcomes is not well understood. This study investigat...
متن کاملThe impact of morphology on light transport in cancellous bone.
In recent years, optical techniques based on diffusion approximation have demonstrated their ability to gain rich spectral information about bone. However, these methods normally assume homogeneity, while cancellous bone and marrow form a highly heterogeneous two-phase medium. This paper studies the limitations of this assumption, and quantifies the role of microstructure on long-range transpor...
متن کاملPredicting Trabecular Bone Stiffness from Clinical Cone-Beam CT and HR-pQCT Data; an In Vitro Study Using Finite Element Analysis
Stiffness and shear moduli of human trabecular bone may be analyzed in vivo by finite element (FE) analysis from image data obtained by clinical imaging equipment such as high resolution peripheral quantitative computed tomography (HR-pQCT). In clinical practice today, this is done in the peripheral skeleton like the wrist and heel. In this cadaveric bone study, fourteen bone specimens from the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of orthopaedic research : official publication of the Orthopaedic Research Society
دوره 27 12 شماره
صفحات -
تاریخ انتشار 2009