Contact between 3 phakic intraocular lens models and the crystalline lens: an anterior chamber optical coherence tomography study.
نویسندگان
چکیده
Three phakic intraocular lens (IOL) models were implanted in 3 different patients. With the usual slitlamp examination, it was not possible to determine whether there was contact between the IOLs and the natural crystalline lens. Using the anterior chamber optical coherence tomography (AC OCT) scanner, direct contact between the natural crystalline lens and the 3 phakic IOLs was revealed. A dynamic study of the contact was performed during accommodation. These observations show that examination of the anterior segment with the AC OCT scanner provides new data about the status of the anterior segment after implantation of phakic IOLs.
منابع مشابه
Transient anterior subcapsular vacuolar change of the crystalline lens in patients after posterior chamber phakic intraocular lens implantation
BACKGROUND We present two cases of transient vacuolar changes in the anterior subcapsular space of the crystalline lens in patients after posterior chamber phakic intraocular lens implantation. CASE PRESENTATION Implantable collamer lenses (ICL) were implanted in healthy myopic patients. Vacuolar changes developed just after the irrigating procedure through the narrow space between the ICL an...
متن کاملInfluence of anterior chamber morphometrics on endothelial cell changes after phakic intraocular lens implantation.
PURPOSE To analyze the position of iris-fixated phakic intraocular lenses (pIOLs) using anterior segment optical coherence tomography (AS-OCT) and evaluate the effect of anterior chamber morphometrics on endothelial cell changes. SETTING Department of Ophthalmology, Academic Hospital Maastricht, The Netherlands. METHODS In this cross-sectional study, AS-OCT was used to measure the distances...
متن کاملBehaviour of the phakic iris-claw intraocular lens (Artisan /Verisyse) during accommodation: an optical coherence biometry study.
PURPOSE To evaluate variations in the position of the phakic iris claw lens (Artisan, Verisyse) and the natural crystalline lens during the accommodation process. METHODS We measured changes in position of the iris claw lens and the crystalline lens during the accommodation using optical coherence biometry (AC Master/Carl Zeiss Meditec, Germany) in 17 patients (28 eyes) with a phakic iris cla...
متن کاملFrom THE DEPARTMENT OF ANTERIOR SEGMENT SURGERY AT ST. ERIK EYE HOSPITAL AND THE DEPARTMENT OF CLINICAL NEUROSCIENCE AT KAROLINSKA INSTITUTET, STOCKHOLM, SWEDEN LONG-TERM RESULTS OF PHAKIC REFRACTIVE LENSES FOR CORRECTION OF MYOPIA AND HYPEROPIA
The phakic refractive lens (PRL) is a silicone lens implanted into the posterior chamber to correct myopia and hyperopia. At the beginning of 2002, when the PRL was introduced at St. Erik Eye Hospital, there had been no reports published on this lens model and therefore the pilot studies of myopic and hyperopic eyes were conducted to investigate the surgical outcome. In the first study, the fir...
متن کاملTraumatic Dislocation of Posterior Chamber Phakic Intraocular Lens into the Berger's Space
Dear Editor, Berger’s space is a potential compartment that can present behind the crystalline lens but is not open in normal situations. This space is formed by the posterior lens surface and anterior vitreous face and is circumscribed by Weiger’s ligament [1]. Except for some congenital abnormalities, Berger’s space is rarely involved in ocular disease because of vulnerability of structures s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 30 9 شماره
صفحات -
تاریخ انتشار 2004