Experimental Evaluation of Drilling Damage on the Strength of Cores Extracted from RC Buildings

نویسندگان

  • A. Digrisolo A. Masi
  • G. Santarsiero
چکیده

Concrete strength evaluated from compression tests on cores is affected by several factors causing differences from the in-situ strength at the location from which the core specimen was extracted. Among the factors, there is the damage possibly occurring during the drilling phase that generally leads to underestimate the actual in-situ strength. In order to quantify this effect, in this study two wide datasets have been examined, including: (i) about 500 core specimens extracted from Reinforced Concrete existing structures, and (ii) about 600 cube specimens taken during the construction of new structures in the framework of routine acceptance control. The two experimental datasets have been compared in terms of compression strength and specific weight values, accounting for the main factors affecting a concrete property, that is type and amount of cement, aggregates' grading, type and maximum size of aggregates, water/cement ratio, placing and curing modality, concrete age. The results show that the magnitude of the strength reduction due to drilling damage is strongly affected by the actual properties of concrete, being inversely proportional to its strength. Therefore, the application of a single value of the correction coefficient, as generally suggested in the technical literature and in structural codes, appears inappropriate. A set of values of the drilling damage coefficient is suggested as a function of the strength obtained from compressive tests on cores. Keywords—RC Buildings, Assessment, In-situ concrete strength, Core testing, Drilling damage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Seismic Pounding on RC Buildings with and without Base Isolation System Subject to Near-Fault Ground Motions

Building pounding occurs between two adjacent buildings with small gap or without sufficient separation distance. It leads to damage buildings during earthquake due to impact. Many researchers have investigated building pounding based on impact force reduction and energy dissipation increase, when two buildings collide with each other. In numerical investigations, using specific link element, i...

متن کامل

Seismic Damage Assessment of RC Buildings Subjected to the Rotational Ground Motion Records Considering Soil-Structure Interaction

The significance of the seismic rotational components have been overlooked in the seismic evaluation of structural behavior. As researchers have measured seismic components more accurately using sensitive rotational velocity sensor, it was observed that the magnitude of rotational components is considerable and could not be neglected. Hence, some parts of seismic damage or failure of structures...

متن کامل

Influence of Real Ground Motion Records in Performance Assessment of RC Buildings

Reinforced concrete frame buildings with Open Ground Story (OGS) are one of the most common building configurations in urban habitat. These configurations are known to be vulnerable to seismic excitations, primarily due to the sudden loss in strength in the ground story and differential stiffness distribution throughout the structure. The differential stiffness distribution is attributed primar...

متن کامل

In situ strength assessment of concrete using recycled aggregates by means of small diameter cores.

By increasing the demolition of old concrete structures and the interest of civil industries to consume cheaper materials, using Recycled Concrete Aggregate (RCA) can cause environmental protection and decrease the construction costs. On the other hand, the high potential of Recycled Aggregate Concrete (RAC) in concrete industry was established by extensive experimental researches were performe...

متن کامل

An Experimental Study on Shear Strengthening of RC Lightweight Deep Beams Using CFRP

. This paper presents the results of an experimental investigation on shear strength enhancement of reinforced concrete deep beams externally reinforced with fiber reinforced polymer (FRP) composites. A total of six deep beam specimens of two different classes, as-built (unstrengthened) and retrofitted were tested in the experimental evaluation program. Two composite systems namely carbon/epoxy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013