Radiation exposure of the spleen during 177Lu-DOTATATE treatment and its correlation with haematological toxicity and spleen volume

نویسندگان

  • Johanna Svensson
  • Linn Hagmarker
  • Tobias Magnander
  • Bo Wängberg
  • Peter Bernhardt
چکیده

BACKGROUND Somatostatin analogue-based radionuclide therapy with (177)Lu-DOTATATE is an important treatment option for patients with advanced neuroendocrine tumours overexpressing somatostatin receptors. In addition to the kidneys, the bone marrow is a major dose-limiting organ. The correlation between developed haematological toxicity and absorbed dose to the bone marrow is poor, which indicates that other factors affect haematological response. The spleen has an important role in the haematopoetic system, including being a reservoir for blood cells. It is also the organ that receives the highest mean absorbed dose during (177)Lu-DOTATATE treatment. The aim of this study was to analyse mean absorbed dose to the spleen and its correlation with haematological toxicity, and to explore changes in splenic volume. The study included 41 patients treated with 7.2 GBq (3.5-8.3 GBq) of (177)Lu-DOTATATE on two to five occasions. Following each fraction, planar whole-body scans were acquired at 2, 24, 48, and 168 h, and a SPECT/CT at 24 h post-injection. Mean absorbed spleen dose was calculated utilising planar images for time-activity data and SPECT to adjust activity amounts. Splenic volume information was collected from diagnostic CT scans at baseline and follow-up. RESULTS Median and total absorbed spleen doses were estimated to 4.5 and 15 Gy, respectively. Total absorbed spleen dose correlated with decrease in Hb (p = 0.02), but not WBC (p = 0.31) or PLT (p = 0.65) counts. For patients without bone metastases, mean absorbed spleen dose correlated with decrease in PLT (p = 0.04) but not Hb (p = 0.16) or WBC (p = 0.42) counts. The spleen volume was reduced to 75 % (p < 0.001) of original values (200 vs. 260 ml) at a mean follow-up of 36 months. CONCLUSIONS Haematological toxicity according to Hb counts was moderately but significantly correlated with total absorbed spleen dose. This supports the possibility that radiation exposure of the spleen affects overall haematological response during (177)Lu-DOTATATE treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel planar image-based method for bone marrow dosimetry in 177Lu-DOTATATE treatment correlates with haematological toxicity

BACKGROUND (177)Lu-DOTATATE is a valuable treatment option for patients with advanced neuroendocrine tumours overexpressing somatostatin receptors. Though well tolerated in general, bone marrow toxicity can, besides renal exposure, become dose limiting and affect the ability to sustain future therapies. The aim of this study was to develop a novel planar image-based method for bone marrow dosi...

متن کامل

Lutetium-177 DOTATATE Production with an Automated Radiopharmaceutical Synthesis System

Objective(s): Peptide Receptor Radionuclide Therapy (PRRT) with yttrium-90 (90Y) and lutetium-177 (177Lu)-labelled SST analogues are now therapy option for patients who have failed to respond to conventional medical therapy. In-house production with automated PRRT synthesis systems have clear advantages over manual methods resulting in increasing use in hospital-based radiopharmacies. We report...

متن کامل

Protective effect of L-carnitine and vitamin E on gastrointestinal tract organs on male rats post radiation exposure

Background: Although ionizing radiation is a risk factor, it is a therapeutic agent for cancer. Objectives: The protective and defensive effect of L-Carnitine and vitamin E on gastrointestinal tract organs (liver, spleen and intestine) post whole body gamma irradiation exposure. Material and methods: 56 male albino rats, which were divided into four groups (14 rats per group); group (I): Contro...

متن کامل

Method dependence, observer variability and kidney volumes in radiation dosimetry of 177Lu-DOTATATE therapy in patients with neuroendocrine tumours

BACKGROUND Radionuclide therapy can be individualized by performing dosimetry. To determine absorbed organ doses in (177)Lu-DOTATATE therapy, three methods based on activity concentrations are currently in use: the small volume of interest (sVOI) method, and two methods based on large VOIs either on anatomical CT (aVOI) or on thresholds on functional images (tVOI). The main aim of the present w...

متن کامل

Estimation of Whole Body Radiation Exposure to Nuclear Medicine Personnel During Synthesis of 177Lutetium-labeled Radiopharmaceuticals

PURPOSE OF THE STUDY With rapid development in the field of nuclear medicine therapy, radiation safety of the personnel involved in synthesis of radiopharmaceuticals has become imperative. Few studies have been done on estimating the radiation exposure of personnel involved in the radio labeling of 177Lu-compounds in western countries. However, data from the Indian subcontinent are limited. We ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2016