A simple, inexpensive, and effective light- carrying laryngoscopic blade for orotracheal intubation of rats.

نویسنده

  • Robert C Molthen
چکیده

The research paradigm of using large laboratory animals, in which oroendotracheal intubations are relatively easy, is shifting toward the use of small animals, such as rodents, in which oropharyngeal access is limited, the arytenoid cartilage cycles are faster, and the glottis is much smaller. The considerable growth recently seen in preclinical imaging studies is accompanied by an increased number of rats and mice requiring in vivo intubation for airway management. Tracheal access is important for ventilation, administration of inhaled anesthetics, instillation of drugs or imaging agents, and maintenance of airway patency to reduce mortality during and after operations. I fashioned a light-carrying laryngoscopic blade (laryngoscope) from readily available acrylic-polymethyl methacrylate tubing and used it to perform rapid, effective tracheal intubation in rats. The laryngoscope design and intubation techniques are presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pyriform Sinus Localization-Assisted Blind Intubation: Comparison with Laryngoscopic Intubation

BACKGROUND Conventional endotracheal intubation requires laryngoscopy for a direct view of the glottis. However, laryngoscopy is associated with many potential complications. The aim of the present study was to compare the efficacy and safety of pyriform sinus localization-assisted blind orotracheal intubation with those of conventional laryngoscopic orotracheal intubation. MATERIAL AND METHO...

متن کامل

Fiberoptic orotracheal intubation on anesthetized patients: do manipulation skills learned on a simple model transfer into the operating room?

BACKGROUND With increasing pressure to use operating room time efficiently, opportunities for residents to learn fiberoptic orotracheal intubation in the operating room have declined. The purpose of this study was to determine whether fiberoptic orotracheal intubation skills learned outside the operating room on a simple model could be transferred into the clinical setting. METHODS First-year...

متن کامل

Cricoid pressure does not increase the rate of failed intubation by direct laryngoscopy in adults.

BACKGROUND Cricoid pressure (CP) is applied during induction of anesthesia to prevent regurgitation of gastric content and pulmonary aspiration. However, it has been suggested that CP makes tracheal intubation more difficult. This double-blind randomized study evaluated the effect of CP on orotracheal intubation by direct laryngoscopy in adults. METHODS Seven hundred adult patients undergoing...

متن کامل

Tracheal intubation: tricks of the trade.

This article describes the use of laryngoscopy for tracheal intubation. Maneuvers basic to successful orotracheal laryngoscopic intubation are described, which should be incorporated into the skill sets of individuals called on to manage the airway in an emergency.

متن کامل

A comparison of the Truview blade with the Macintosh blade in adult patients.

The Truview blade facilitates a view of the vocal cords by indirect laryngoscopy. We prospectively compared the view obtained at laryngoscopy and intubating conditions of Truview (Group 1) or Macintosh (Group 2) blades in 170 patients who were scheduled to undergo general anaesthesia. We studied pre-operative airway evaluation, laryngoscopic view, duration of intubation, maximal force applied d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Association for Laboratory Animal Science : JAALAS

دوره 45 1  شماره 

صفحات  -

تاریخ انتشار 2006