897Feasibility of Using Existing Public and Private Data Sources for Nationwide Medical Device Post-marketing Safety Surveillance
نویسندگان
چکیده
Background. The Food and Drug Administration (FDA) initiated a national strategy for monitoring post-market medical product safety using existing public and private electronic data. The Centers for Medicare and Medicaid Services (CMS) publicly report hospital central line-associated bloodstream infection (CLA-BSI) data. We explored the feasibility of expanding the current FDA Sentinel Initiatives on patient-level data to hospital-level data for surveillance of CLA-BSI associated with intravenous needleless connectors (NC). Methods. We merged the 2013 CMS Hospital Compare CLA-BSI data with the MaxPlusTM Tru-SwabTM Positive Displacement Connector (MP) client database from CareFusion to identify hospitals using the MPs (MP hospitals) vs those not using the MPs (Comparator hospitals). MP is a newer generation of NC with enhanced patient safety engineering design features. We evaluated CLA-BSI rates associated with MPs vs Comparators. Results. In the CMS Hospital Compare CLA-BSI database, 3,074 hospitals reported central line (CL) days >1, with 25% (n = 758) hospitals using MP NCs. The MP hospitals accounted for 30% (2,923,859/ 9,887,264) of CL days, and 28% (3,017/ 10,864) of CLA-BSI episodes. The MP hospitals had a lower observed CLA-BSI rate (1.03 per 1,000 CL days [3,017 CLA-BSIs / 2,923,859 CL-days]) compared to Comparator hospitals (1.13 per 1,000 CL days [7,847 CLA-BSIs / 6,963,405 CL-days], P < 0.0001). The univariate relative risk for CLA-BSI of MP hospitals was 0.91 (95% CI: 0.83, 0.98; P = 0.02). After adjusting for hospital bed size, teaching, urban status, and geographic regions, the multivariable relative risk for CLA-BSI of MP hospitals was 0.94 (95% CI: 0.86, 1.02; P = 0.11). Conclusion. We demonstrated that it is feasible to link hospital-level data from public-private sources to support the FDA’s electronic post-market medical device safety surveillance efforts. Manufacturers should be encouraged to participate in FDA’s efforts. Disclosures. Y. P. Tabak, CareFusion: Employee and Shareholder, Salary R. Johannes, CareFusion: Employee and Shareholder, Salary X. Sun, CareFusion: Employee, Salary C. Crosby, CareFusion: Employee and Shareholder, Salary W. Jarvis, Baxter: Consultant, Consulting fee; CareFusion: Consultant, Consulting fee; Johnson and Johnson: Consultant, Consulting fee; Gojo: Consultant, Consulting fee
منابع مشابه
Evaluation of Aryoseven Safety (Recombinant Activated Factor VII) in Patients with Bleeding Disorders (An Observational Post-Marketing Surveillance Study)
Background: Recombinant activated factor VII induces hemostasis in patients with coagulopathy disorders. AryoSeven™ as a safe Iranian Recombinant activated factor VII has been available on our market. This study was performed to establish the safety of AryoSeven on patients with coagulopathy disorder. Methods: This single-center, descriptive,...
متن کاملSocial Media Listening for Routine Post-Marketing Safety Surveillance.
INTRODUCTION Post-marketing safety surveillance primarily relies on data from spontaneous adverse event reports, medical literature, and observational databases. Limitations of these data sources include potential under-reporting, lack of geographic diversity, and time lag between event occurrence and discovery. There is growing interest in exploring the use of social media ('social listening')...
متن کاملDid narcolepsy occur following administration of AS03-adjuvanted A(H1N1) pandemic vaccine in Ontario, Canada? A review of post-marketing safety surveillance data.
A vaccine safety signal and association between new onset of narcolepsy and AS03-adjuvanted pandemic influenza A(H1N1) vaccine (Pandemrix, GlaxoSmithKline) in children and young adults has been reported in several European countries. In Ontario, Canada, AS03-adjuvanted pandemic A(H1N1) vaccine (Arepanrix, GlaxoSmithKline) was the primary vaccine administered in 2009/10, with 4.8 million doses d...
متن کاملPatient safety goals for the proposed Federal Health Information Technology Safety Center
The Office of the National Coordinator for Health Information Technology is expected to oversee creation of a Health Information Technology (HIT) Safety Center. While its functions are still being defined, the center is envisioned as a public-private entity focusing on promotion of HIT related patient safety. We propose that the HIT Safety Center leverages its unique position to work with key a...
متن کاملPost Marketing Surveillance on Propranolol and Atenolol Tablets Manufactured in Iran
Propranolol, a prototypical b-adrenergic receptor antagonist and atenolol, a cardio-selective b-antagonist are widely used in therapeutic regimens for treatment of hypertensive patients. In Iran, several pharmaceutical manufacturers formulate these two b-blockers. As the formulation of a dosage form is essential for the patient's safety and drug efficacy, in this study we aimed to evalu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 1 شماره
صفحات -
تاریخ انتشار 2014