A randomized, seven-day study to assess the efficacy and safety of a glycopyrrolate/formoterol fumarate fixed-dose combination metered dose inhaler using novel Co-Suspension™ Delivery Technology in patients with moderate-to-very severe chronic obstructive pulmonary disease
نویسندگان
چکیده
BACKGROUND Long-acting muscarinic antagonist/long-acting β2-agonist combinations are recommended for patients whose chronic obstructive pulmonary disease (COPD) is not managed with monotherapy. We assessed the efficacy and safety of glycopyrrolate (GP)/formoterol fumarate (FF) fixed-dose combination delivered via a Co-Suspension™ Delivery Technology-based metered dose inhaler (MDI) (GFF MDI). METHODS This was a Phase IIb randomized, multicenter, placebo-controlled, double-blind, chronic-dosing (7 days), crossover study in patients with moderate-to-very severe COPD ( NCT01085045 ). Treatments included GFF MDI twice daily (BID) (GP/FF 72/9.6 μg or 36/9.6 μg), GP MDI 36 μg BID, FF MDI 7.2 and 9.6 μg BID, placebo MDI, and open-label formoterol dry powder inhaler (FF DPI) 12 μg BID or tiotropium DPI 18 μg once daily. The primary endpoint was forced expiratory volume in 1 s area under the curve from 0 to 12 h (FEV1 AUC0-12) on Day 7 relative to baseline FEV1. Secondary endpoints included pharmacokinetics and safety. RESULTS GFF MDI 72/9.6 μg or 36/9.6 μg led to statistically significant improvements in FEV1 AUC0-12 after 7 days' treatment versus monocomponent MDIs, placebo MDI, tiotropium, or FF DPI (p ≤ 0.0002). GFF MDI 36/9.6 μg was non-inferior to GFF MDI 72/9.6 μg and monocomponent MDIs were non-inferior to open-label comparators. Pharmacokinetic results showed glycopyrrolate and formoterol exposure were decreased following administration via fixed-dose combination versus monocomponent MDIs; however, this was not clinically meaningful. GFF MDI was well tolerated. CONCLUSIONS GFF MDI 72/9.6 μg and 36/9.6 μg BID improve lung function and are well tolerated in patients with moderate-to-very severe COPD. TRIAL REGISTRATION ClinicalTrials.gov NCT01085045 . Registered 9 March 2010.
منابع مشابه
Erratum to: A randomized, seven-day study to assess the efficacy and safety of a glycopyrrolate/formoterol fumarate fixed-dose combination metered dose inhaler using novel Co-Suspension™ Delivery Technology in patients with moderate-to-very severe chronic obstructive pulmonary disease
Erratum Upon Publication of the original article [1] several discrepancies were highlighted in the following sections; Results, Table 1, Table 2 and Fig. 3. These errors have since been acknowledged and corrected in this erratum The first sentence in the subsection “Baseline characteristics” originally read: Patients’ baseline and demographic characteristics are shown in Table 1 (mITT populatio...
متن کاملA randomized, seven-day study to assess the efficacy and safety of a glycopyrrolate/formoterol fumarate fixed-dose combination metered dose inhaler using novel Co-SuspensionTM Delivery Technology in patients with moderate-to-very severe chronic obstructive pulmonary disease
Background: Long-acting muscarinic antagonist/long-acting β2-agonist combinations are recommended for patients whose chronic obstructive pulmonary disease (COPD) is not managed with monotherapy. We assessed the efficacy and safety of glycopyrrolate (GP)/formoterol fumarate (FF) fixed-dose combination delivered via a Co-SuspensionTM Delivery Technology-based metered dose inhaler (MDI) (GFF MDI)....
متن کاملPharmacokinetics of glycopyrronium/formoterol fumarate dihydrate delivered via metered dose inhaler using co-suspension delivery technology in patients with moderate-to-very severe COPD
Purpose The efficacy and tolerability of GFF MDI (Bevespi Aerosphere®), a fixed-dose combination of glycopyrronium (GP)/formoterol fumarate dihydrate (FF) 14.4/10 μg (equivalent to glycopyrrolate/formoterol fumarate 18/9.6 μg) delivered by metered dose inhaler (MDI) using innovative co-suspension delivery technology, has been investigated in a Phase III clinical trial program (NCT01854645, NCT0...
متن کاملDose-response to inhaled glycopyrrolate delivered with a novel Co-Suspension™ Delivery Technology metered dose inhaler (MDI) in patients with moderate-to-severe COPD
BACKGROUND This study forms part of the first complete characterization of the dose-response curve for glycopyrrolate (GP) delivered using Co-Suspension™ Delivery Technology via a metered dose inhaler (MDI). We examined the lower GP MDI dose range to determine an optimal dose for patients with moderate-to-severe chronic obstructive pulmonary disease (COPD). METHODS This randomized, double-bli...
متن کاملA phase IIb randomized, chronic-dosing, incomplete block, cross-over study of glycopyrronium, delivered via metered dose inhaler, compared with a placebo and an active control in patients with moderate-to-severe COPD
BACKGROUND Long-acting muscarinic antagonist (LAMA) and long-acting β2-agonist (LABA) bronchodilators are key to the pharmacologic treatment of chronic obstructive pulmonary disease (COPD). This Phase IIb study investigated the safety and efficacy of four doses of the LAMA glycopyrronium (GP) delivered using co-suspension delivery technology via metered dose inhaler (MDI). The study was part of...
متن کامل