Impaction grafting of the acetabulum with ceramic bone graft substitute mixed with femoral head allograft: High survivorship in 43 patients with a median follow-up of 7 years
نویسندگان
چکیده
BACKGROUND AND PURPOSE Restoration of bone stock at revision hip surgery remains a challenge. Alternative graft materials with suitable mechanical properties for impaction grafting have been sought due to issues with infection, antigenicity, cost, and availability of allograft. We have previously presented good short-term results of the use of BoneSave, a biphasic porous ceramic bone graft substitute, consisting of sintered 80% tricalcium phosphate and 20% hydroxyapatite, in a 50:50 mix with femoral head allograft. We now present the medium-term results. METHODS We conducted a retrospective review of a cohort of 43 consecutive patients undergoing impaction grafting of contained acetabular defects by multiple surgeons at a single center. 34 patients received uncemented acetabular components and 9 received cemented components. Patients were followed up radiographically and with the self-reported satisfaction scale (SAPS), Oxford hip score (OHS), and the Short-Form 12 (SF12) health survey. Kaplan-Meier survivorship analysis was performed with revision of the acetabular component, revision of any part of the construct, and reoperation as endpoints. RESULTS The fate of all cases was known. Median follow-up of the surviving patients was 80 (69-106) months. 15 patients died during the follow-up period, 14 with their construct in situ. The survivorship of the grafted acetabulum and acetabular component was 94% (95% CI: 99-78) at 7 years. 1 patient had been revised for aseptic loosening of the acetabulum and 1 for deep infection. The mean OHS was 31 (SD 12), the mean SF12 physical-component score (PCS) was 38 (SD 13), the median SAPS was 83 (0-100), and the median SF12 mental-component score (MCS) was 55 (23-65). The graft material became incorporated in all 3 zones of the acetabulum in 23 out of 24 cases that had complete radiographic follow-up. INTERPRETATION These medium-term results show that BoneSave is a reliable material for impaction grafting of the acetabulum when used in conjunction with femoral head allograft.
منابع مشابه
Impaction grafting of the acetabulum with ceramic bone graft substitute
BACKGROUND AND PURPOSE Loss of bone stock remains a challenge in revision hip surgery. Grafting with allograft is well established, but there are problems with availability, cost, infection, antigenicity, reproducibility, and stability of the created construct. BoneSave is a biphasic porous ceramic consisting of sintered 80% tricalcium phosphate and 20% hydroxyapatite. In vitro and in vivo stud...
متن کاملImpaction bone grafting of the acetabulum at hip revision using a mix of bone chips and a biphasic porous ceramic bone graft substitute
BACKGROUND AND PURPOSE One of the greatest problems of revision hip arthroplasty is dealing with lost bone stock. Good results have been obtained with impaction grafting of allograft bone. However, there have been problems of infection, reproducibility, antigenicity, stability, availability of bone, and cost. Thus, alternatives to allograft have been sought. BoneSave is a biphasic porous cerami...
متن کاملTreatment of Femoral Head Osteonecrosis (Stages 2B, 3 Ficat) Through Open Direct Core Decompression by Allograft Impaction and Light Bulb Technique
Background: Femoral head avascular necrosis is the cause of paralyzing status of youth population. Initial diagnosisis the main element in treating the disease. Bone grafting and core decompression are the approved cures at the earlysteps of the disease. Hip replacement in a total manner is the common cure in the final stages. The optimal treatment inthe intermediate stages is...
متن کاملImpaction grafting of the acetabulum with a mixture of frozen, ground irradiated bone graft and porous synthetic bone substitute (Apapore 60).
The clinical and radiological results of 50 consecutive acetabular reconstructions in 48 patients using impaction grafting have been retrospectively reviewed. A 1:1 mixture of frozen, ground irradiated bone graft and Apapore 60, a synthetic bone graft substitute, was used in all cases. There were 13 complex primary and 37 revision procedures with a mean follow-up of five years (3.4 to 7.6). The...
متن کاملFemoral impaction grafting with cement in revision total hip replacement. Evolution of the technique and results.
We report the results of cancellous femoral impaction grafting with cement in revision hip arthroplasty in all patients from one centre who had undergone surgery more than five years previously. A total of 32 surgeons undertook femoral impaction grafting in 207 patients (226 hips). There were no deaths attributable to the revision surgery; 33 patients with 35 functioning hips died with less tha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 84 شماره
صفحات -
تاریخ انتشار 2013