Comparison of the Disposable Streamlined Liner of the Pharynx Airway and the Disposable I-gel in Anaesthetized, Paralyzed Adults: A Randomized Prospective Study.

نویسندگان

  • Khaled El-Radaideh
  • Ala A Alhowary
  • Diab Bani Hani
چکیده

Introduction. This study compared streamlined liner of the pharynx airway (SLIPA) and I-gel noninflatable, single-use, supraglottic airway device (SAD) performance in anesthetized, paralyzed adults. Methods. Eighty adults (ASA physical statuses I-III) who were undergoing elective procedures under general anesthesia with an SAD were enrolled in this prospective, randomized, single-blind study. Subjects were randomly and evenly assigned to the SLIPA or I-gel group for intraoperative airway management. Ease and number of insertions, insertion time, oropharyngeal sealing pressure, hemodynamic response, oxygen saturation (SpO2), end-tidal CO2 (EtCO2), and peri- and postoperative complications were examined. Results. The SLIPA and I-gel devices were successfully inserted in 100% and 95% of subjects, respectively. In two I-gel subjects (5%), ventilation was not possible after two attempts, but a size 55 SLIPA was successfully inserted in both cases. Forty-two and 38 patients were ultimately included in the SLIPA and I-gel groups, respectively. Insertion time was significantly shorter with the SLIPA (11.19 ± 3.03 s) than with the I-gel (15.05 ± 6.37 s, P = 0.003). Oropharyngeal sealing pressure was significantly higher in SLIPA (28.76 ± 3.11 cmH2O) than in I-gel (25.9 ± 3.65 cmH2O) subjects (P = 0.001). Blood staining occurred more frequently in SLIPA (n = 8, 19.0%) than in I-gel (n = 5, 13.2%) patients (P < 0.01). Heart rate, mean arterial blood pressure, SpO2, and EtCO2 were not significantly different between groups. Conclusion. Although blood staining incidence was higher, SLIPA insertion was easier and faster than I-gel insertion. The SLIPA provided better airway sealing pressure. Both devices had similar mechanical ventilation and oxygenation characteristics and comparable hemodynamic stability. Both noninflatable SADs are useful, but SLIPA rapid insertion and good airway sealing make it an effective alternative to the I-gel.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of four airway training manikins as patient simulators for the insertion of eight types of supraglottic airway devices.

We evaluated the performance of four currently available manikins: Airway Management Trainer (Ambu, UK), Airway Trainer (Laerdal, Norway), Airsim (Trucorp, Ireland), 'Bill 1' (VBM, Germany), with eight supraglottic airway devices: Airway Management Device, Cobra Perilaryngeal Airway, Combitube, i-Gel, Laryngeal Tube, Laryngeal Tube Disposable, Laryngeal Tube Suction II and Streamlined Liner of ...

متن کامل

Comparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries

Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...

متن کامل

Evaluation of Ecological Factors Regarding the Use of Disposable Containers

 Introduction: Excessive consumption of disposable containers, and specifically the plastic ones, has adverse effects on ecosystem and the community's health. To identify ecological factors (individual, interpersonal and social) related to these containers, this study aimed to specify the most important factors according to the participants. Methods: This was a qualitative content analysis  co...

متن کامل

آلودگی میکروبی و مقاومت آنتی بیوتیکی باکتری های ایزوله شده در ظروف یکبار مصرف غذایی شهر همدان

Introduction: The widespread application of disposable food containers in Iranian society has been rapidly increased. Scientific evaluation for detecting problems of such containers and their microbial contamination is necessarily inevitable. The aim of this study was to determine the level of contamination in plastic and plant disposable food containers and examining the antibiotic resistances...

متن کامل

Comparative Clinical Evaluation of Proseal Lma with I - Gel Airway in Patients Undergoing Elective Surgical Procedures under General Anaesthesia

The laryngeal mask airway devices dominate the field of supraglottic airway management and are widely being used in clinical practice. The disposable one is the preferred variety because it avoids the risk of contamination. A new disposable supraglottic airway device the i-gel airway has been introduced recently. We have compared the disposable soft seal LMA with i-gel airway in terms of variou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology research and practice

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015