[Validation of segmentation techniques for positron emission tomography using ex-vivo images of oncological surgical specimens].
نویسندگان
چکیده
OBJECTIVE To design a novel ex-vivo acquisition technique to establish a common framework to validate different segmentation techniques for oncological PET images. To evaluate several automatic segmentation algorithms on this set of images. MATERIAL AND METHODS In 15 patients with cancer, ex-vivo PET studies of surgical specimens removed during surgery were performed after injection of (18)F-FDG. Images were acquired in two scanners: a clinical PET/CT and a high-resolution PET scanner. Real tumor volume was determined in each patient, and a reference image was generated for segmentation of each tumor. Images were segmented with 12 automatic algorithms and with a standard method for PET (relative threshold at 42%) and results were evaluated by quantitative parameters. RESULTS It has been possible to demonstrate by segmentation of PET images of surgical specimens that on high resolution PET images, 8 out of 12 evaluated segmentation techniques outperformed the standard method, whose value is 42%. However, none of the algorithms outperformed the standard method when applied on images from the clinical PET/CT. Due to the great interest of this set of PET images, all studies have been published on the Internet in order to provide a common framework for validation and comparison of different segmentation techniques. CONCLUSIONS We have proposed a novel technique to validate segmentation techniques for oncological PET images, acquiring ex-vivo PET studies of surgical specimens. We have demonstrated the usefulness of this set of PET images by evaluating several automatic segmentation algorithms.
منابع مشابه
Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction
Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...
متن کاملSystemic atherosclerotic plaque vulnerability in patients with Coronary Artery Disease with a single Whole Body [FDG]PET-CT scan
Objective(s): Cardiovascular disease is a leading cause of morbimortality with over half cardiovascular events occurring in the asymptomatic population by traditional risk stratification. This preliminary study aimed to evaluate systemic plaque vulnerability in patients with prior Coronary Artery Disease (CAD) with a single Whole Body [FDG] PET-CT scan in terms of plaq...
متن کاملContribution of 68Ga-PSMA PET/CT to targeting volume delineation of prostate cancer treated with conformal radiation therapy: Which SUV threshold is appropriate?
Introduction: Prostate-specific membrane antigen (PSMA) has been demonstrated as a promising tool for specific imaging of prostate cancer (PCa) via positron emission tomography-computed tomography (PET/CT) scanning. Radiation treatment planning (RTP) based on 68Ga-PSMA PET/CT scanning can also lead to some decision modifications. The specific goal o...
متن کاملDetection of Alzheimer\\\\\\\'s Disease using Multitracer Positron Emission Tomography Imaging
Alzheimer's disease is characterized by impaired glucose metabolism and demonstration of amyloid plaques. Individual positron emission tomography tracers may reveal specific signs of pathology that is not readily apparent on inspection of another one. Combination of multitracer positron emission tomography imaging yields promising results. In this paper, 57 Alzheimer's disease neuroimaging ini...
متن کاملImportance of defect detectability in Positron Emission Tomography imaging of abdominal lesions
Objective(s): This study was designed to assess defect detectability in positron emission tomography (PET) imaging of abdominal lesions. Methods: A National Electrical Manufactures Association International Electrotechnical Commission phantom was used. The simulated abdominal lesion was scanned for 10 min using dynamic list-mode acquisition method. Images, acquired with scan duration of 1-10 mi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Revista espanola de medicina nuclear e imagen molecular
دوره 33 2 شماره
صفحات -
تاریخ انتشار 2014