Repeatability of corneal first-surface wavefront aberrations measured with Pentacam corneal topography.

نویسندگان

  • Hema Shankar
  • Deepa Taranath
  • Chandramalar T Santhirathelagan
  • Konrad Pesudovs
چکیده

PURPOSE To assess the repeatability of corneal wavefront aberrations derived from Pentacam (Oculus) corneal topography. SETTING Flinders Eye Centre, Flinders Medical Centre, Bedford Park, South Australia, Australia. METHODS Forty-five normal participants and 10 participants with keratoconus were tested. Intraobserver and interobserver repeatability was determined using 4 observers within and between sessions. Topographical maps were exported to external software, and corneal first-surface wavefront aberrations were calculated using a 10th-order Zernike expansion over a 6.0 mm optical zone. Repeatability was determined with Bland-Altman limits of agreement and expressed as the coefficient of repeatability (COR). RESULTS Initial data showed high wavefront aberrations in normal participants and poor repeatability. Topographical maps showed extrapolated topography in zones without data acquisition; maps with less than 6.0 mm of complete data were excluded in the final analysis. The mean wavefront aberrations for normal participants remained high, but repeatability improved. The COR relative to the magnitude of wavefront aberrations was high (average 100%) across all modal pairs and orders, although best for total higher-order root mean square. Participants with keratoconus had higher magnitude wavefront aberrations and poorer repeatability but similar COR to average wavefront aberration ratios. Examination of raw elevation data showed poor repeatability. CONCLUSIONS Wavefront aberrations calculated from Pentacam corneal topography were large in magnitude, and reliability was poor, largely due to variability in corneal elevation data. Intraobserver and interobserver reliability within and between sessions was comparable. The Pentacam was not reliable in measuring corneal wavefront aberrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Repeatability and concordance of the Pentacam system. Comparative study of corneal parameters measured with Pentacam and Atlas Repetibilidad y concordancia de un sistema Pentacam. Comparación de parámetros corneales medidos con Pentacam y con Atlas

REFERENCES AND LINKS [1] W. N. Charman, “The retinal image in the human eye”, in Progress in Retinal Research, Pergamon, Oxford (1983). [2] A. A. Atchison, G. Smith, Optics of the Human Eye, Butterworth-Heinnemann, Oxford (2000). [3] P. Artal, A. Guirao, “Contribution of corneal and lens to the aberrations of the human eye”, Opt. Lett. 23, 1713-1715 (1998). [4] A. Guirao, P. Artal, “Corneal wav...

متن کامل

Compensation of corneal horizontal/vertical astigmatism, lateral coma, and spherical aberration by internal optics of the eye.

Both the anterior surface of the cornea and the internal optics (the posterior cornea, crystalline lens) contribute to the aberration of a wavefront passing through the eye. Artal, Guirao, Berrio, and Williams (2001) reported that the wavefront aberrations produced by the internal optics offset, or compensate for, the aberrations produced by the cornea to reduce ocular wavefront aberrations. We...

متن کامل

Optical response to LASIK surgery for myopia from total and corneal aberration measurements.

PURPOSE To evaluate the optical aberrations induced by LASIK refractive surgery for myopia on the anterior surface of the cornea and the entire optical system of the eye. METHODS Total and corneal aberrations were measured in a group of 14 eyes (preoperative myopia ranging from -2.5 to -13 D) before and after LASIK surgery. Total aberrations were measured using a laser ray-tracing technique. ...

متن کامل

The use of NIDEK OPD Scan II wavefront aberrometry in toric intraocular lens implantation.

PURPOSE To present case examples outlining the use of wavefront aberrometry for toric intraocular lens (IOL) implantation pre- and postoperatively. METHODS Twelve eyes that underwent AcrySof Toric IOL (Alcon Inc Laboratories) implantation were assessed pre- and postoperatively using the NIDEK OPD Scan II (NIDEK Co Ltd). Wavefront aberrometry, corneal topography, and objective visual quality w...

متن کامل

Precision of NIDEK OPD-scan measurements.

PURPOSE To evaluate the repeatability of wavefront measurements using the NIDEK OPD-Scan. METHODS A total of 179 eyes from 90 healthy volunteers (57 women and 33 men) with no corneal or lenticular pathology and normal visual acuity were enrolled in this study. Mean patient age was 39 years (range: 17 to 85 years). All patients underwent four consecutive measurements by one examiner with the N...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 34 5  شماره 

صفحات  -

تاریخ انتشار 2008