An MRI-Compatible High Frequency AC Resistive Heating System for Homeothermic Maintenance in Small Animals

نویسندگان

  • Stuart Gilchrist
  • Ana L Gomes
  • Paul Kinchesh
  • Veerle Kersemans
  • Philip D Allen
  • Sean C Smart
چکیده

PURPOSE To develop an MRI-compatible resistive heater, using high frequency alternating current (AC), for temperature maintenance of anaesthetised animals. MATERIALS AND METHODS An MRI-compatible resistive electrical heater was formed from narrow gauge wire connected to a high frequency (10-100 kHz) AC power source. Multiple gradient echo images covering a range of echo times, and pulse-acquire spectra were acquired with the wire heater powered using high frequency AC or DC power sources and without any current flowing in order to assess the sensitivity of the MRI acquisitions to the presence of current flow through the heater wire. The efficacy of temperature maintenance using the AC heater was assessed by measuring rectal temperature immediately following induction of general anaesthesia for a period of 30 minutes in three different mice. RESULTS Images and spectra acquired in the presence and absence of 50-100 kHz AC through the wire heater were indistinguishable, whereas DC power created field shifts and lineshape distortions. Temperature lost during induction of anaesthesia was recovered within approximately 20 minutes and a stable temperature was reached as the mouse's temperature approached the set target. CONCLUSION The AC-powered wire heater maintains adequate heat input to the animal to maintain body temperature, and does not compromise image quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Viability of Oil Extraction from Trinidad Tar Sands by Radio Frequency Heating: A Simulation Approach

Trinidad has tar sand resources of about 2 billion barrels of oil on land in the Parrylands/Guapo and Brighton areas. With an oil price of over USD 25 per barrel, the commercial extraction of oil from Trinidad tar sands is viable, but it requires a careful study. The relatively small extent of this tar sand (about 10,000 acres and with depths varying from surface to less than 500 feet) and with...

متن کامل

Design and Implementation of High Frequency Inverter Operation for Induction Heating Cooking Application Using PSIM Software

An inverter circuit which generates a output high frequency AC. A low frequency AC (LFAC) to high frequency AC (HFAC) power conversion system without a DC smoothing Capacitor filter is introduced. The operating principle of a utility frequency AC-high frequency AC power frequency conversion circuit defined as a high frequency inverter is described. This synthesized converter can be considered a...

متن کامل

ac-mode atomic force microscope imaging in air and solutions with a thermally driven bimetallic cantilever probe

An ac imaging mode for atomic force microscopy ~AFM! has been developed that employs a thermally driven bimetallic cantilever to sense surface topography. Oscillations are induced in a composite cantilever, comprising a Si3N4 layer and Au overcoat, by local heating with a resistive wire heater placed in close proximity to the cantilever. Cantilever bending occurs upon heating due to the differe...

متن کامل

A Novel Active Filter for Mitigation of EMI and Other Adverse Effects of PWM Inverter-Fed AC Motor

This paper presents novel active filter for mitigation electromagnetic interference (EMI) and other adverse effects of pulse width modulation (PWM) inverter-fed AC motor system. An active filter proposed and devised for this system is characterized by sophisticated connection of two small separate filters, capable of mitigating all the adverse effects. This paper provides high frequency models ...

متن کامل

Voltage-based device tracking in a 1.5 Tesla MRI during imaging: initial validation in swine models.

PURPOSE Voltage-based device-tracking (VDT) systems are commonly used for tracking invasive devices in electrophysiological cardiac-arrhythmia therapy. During electrophysiological procedures, electro-anatomic mapping workstations provide guidance by integrating VDT location and intracardiac electrocardiogram information with X-ray, computerized tomography, ultrasound, and MR images. MR assists ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016