Cyclic fatigue of Profile rotary instruments after simulated clinical use.
نویسندگان
چکیده
AIM The purpose of this study was to evaluate cyclic fatigue of Profile Ni-Ti rotary instruments (PRIs) after dry heat sterilization and up to 10 times simulated clinical use. METHODOLOGY Instruments of size 40-15 were used in a crown-down technique. Three groups were included in this study. In groups 1 and 2, each set of instruments was used in five and 10 canals, respectively. Group 3 was the control group. NaOCl at a concentration of 2.5% was used as an irrigant. Each set of instruments was sterilized before each use. RESULTS The PRI size 40 demonstrated the lowest incidence of rotations to breakage. One-way analysis of variance and Turkey's HSD test showed statistically significant differences among different file sizes within each group. CONCLUSIONS The results showed that dry heat sterilization and simulated clinical use in the presence of NaOCl did not lead to a decrease in the number of rotations to breakage of the files.
منابع مشابه
Cyclic fatigue resistance of rotary NiTi instruments after simulated clinical use in curved root canals.
The aim of this study was to assess cyclic fatigue resistance in rotary nickel-titanium instruments after simulated clinical use in curved root canals (40-degree, 5-mm radius curve). Thirty-six RaCe rotary NiTi files, size #5, taper 0.04, were divided into 3 groups: Groups A, B and C with one, three and five cycles of use, respectively. Time to failure was recorded with a stopwatch in seconds a...
متن کاملCyclic fatigue testing of three different rotary nickel titanium endodontic instruments in simulated curved canals - an in vitro sem analysis.
INTRODUCTION Instrument separation is a serious concern in endodontics. Stainless steel instruments usually deform before they separate whereas Nickel Titanium instruments do not show any sign of deformation. AIM of the present study was to compare the cyclic rotations needed to fracture three different rotary nickel titanium endodontic instruments namely Profile, K3 Endo, RaCe in simulated c...
متن کاملCyclic fatigue behavior of nickel-titanium dental rotary files in clinical simulated root canals.
BACKGROUND/PURPOSE Dental rotary instruments can be applied in multiple conditions of canals, but unpredictable fatigue fracture may happen. This study evaluated the fatigue lives of two batches of nickel-titanium (NiTi) dental rotary files operating in clinically simulated root canals. METHODS Single-step cyclic fatigue tests were carried out to assess the performance of two batches of NiTi ...
متن کاملStructural analysis of cyclic-loaded nickel-titanium rotary instruments by using resonance frequency as a parameter.
INTRODUCTION The aim of this study was to investigate the relationship between fatigue life and resonance frequency (RF) of various types of nickel-titanium (NiTi) rotary instruments. In addition, the influence of NiTi instruments with different manufacturing methods on cyclic loading was evaluated by using RF as a parameter. METHODS Twenty-eight ProFile instruments and 10 Twisted File instru...
متن کاملComparison of cyclic fatigue and torsional resistance in reciprocating single-file systems and continuous rotary instrumentation systems.
As compared with continuous rotary systems, reciprocating motion is believed to increase the fatigue resistance of NiTi instruments. We compared the cyclic fatigue and torsional resistance of reciprocating single-file systems and continuous rotary instrumentation systems in simulated root canals. Eighty instruments from the ProTaper Universal, WaveOne, MTwo, and Reciproc systems (n = 20) were s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International endodontic journal
دوره 32 2 شماره
صفحات -
تاریخ انتشار 1999