A comparison of dose distribution from Manchester-style and Fletcher-style intracavitary brachytherapy applicator systems in cervical cancer
نویسندگان
چکیده
PURPOSE During intracavitary brachytherapy (ICBT) for cervical cancer, the choice of applicator system remains rather arbitrary. However, as the applicator geometry may play an important role in dose distribution, thereby improving the therapeutic ratio, this study was conducted to compare the Manchester-style and Fletcher-style applicator systems. MATERIAL AND METHODS After completion of EBRT, 22 patients with cervical cancer (stage IIA-IIIB) underwent intracavitary brachytherapy. Two different types of applicators: Manchester-style and Fletcher-style were used for each patient for alternate insertions. The purpose was to compare the dose distribution obtained when two different applicators were applied to the same patient. CT based computerized treatment planning was done and dose was prescribed to point A. After optimization, height, width and thickness of the 100% isodose curve, as well as the 100% isodose volume were noted. Dose received by the urinary bladder and rectum were noted. RESULTS The 100% isodose volume and its maximum width were significantly greater (P value < 0.0001 in both occasions) when Manchester-style applicator was used. However, the dose received by 0.1 cc, 1.0 cc and 2.0 cc of the urinary bladder were all significantly greater (P value < 0.0001) with the Manchester-style applicator. No significant difference was found in rectal doses. CONCLUSIONS The larger 100% isodose volume, as well as the greater width achieved with the use of Manchester-style applicator can be helpful in circumstances where the tumour is large in size. However, this must be balanced against the increased dose received by the urinary bladder.
منابع مشابه
Comparison of dose volume parameters evaluated using three forward planning – optimization techniques in cervical cancer brachytherapy involving two applicators
Purpose This study is intended to compare dose-volume parameters evaluated using different forward planning- optimization techniques, involving two applicator systems in intracavitary brachytherapy for cervical cancer. It looks for the best applicator-optimization combination to fulfill recommended dose-volume objectives in different high-dose-rate (HDR) fractionation schedules. Material and ...
متن کاملDosimetric Comparison of Fixed and Flexible Geometry ICRT Applicators in Patients Treated for Carcinoma Cervix
In intracavitary radiotherapy (ICRT) for cancer cervix, applicator geometry has the potential to impact the doses to organs at risk (OARs) and the coverage of the target volume. At our centre two Varian made Fletcher-style applicator sets, namely defined (fixed) geometry and flexible geometry, are used for ICRT. In the present work, the two types of applicators were compared dosimetrically as p...
متن کاملDosimetric evaluation of a newly designed low dose rate brachytherapy applicator for treatment of cervical cancer with extension into the lower vagina
Currently, patients having cervical cancer with extension into the lower vagina are being treated with a combination of the Fletcher-Suit applicator, which treats the cervix, and a vaginal cylinder, which treats the lower vagina. With this method, patients receive two separate implants-a procedure that creates greater uncertainty in the dose distribution and unnecessary patient inconvenience. T...
متن کاملComparison of dose–volume analysis between standard Manchester plan and magnetic resonance image-based plan of intracavitary brachytherapy for uterine cervical cancer
To investigate the feasibility of image-based intracavitary brachytherapy (IBICBT) for uterine cervical cancer, we evaluated the dose-volume histograms (DVHs) for the tumor and organs at risk (OARs) and compared results from the IBICBT plan and the standard Manchester system (Manchester plan) in eight patients as a simulation experiment. We performed magnetic resonance imaging (MRI) and compute...
متن کاملThe usefulness of fleet rectal enemas on high-dose-rate intracavitary cervical cancer brachytherapy. A prospective trial
PURPOSE To evaluate the effects of rectal enemas on rectal doses during radical high-dose-rate (HDR) intracavitary cervical brachytherapy (BT). MATERIAL AND METHODS Twenty patients suffering from cervical cancer and treated with external beam radiotherapy and HDR-BT were included in a prospective trial. The first brachytherapy fraction was considered the basal status, and patients were instru...