Cementless acetabular cups for primary total hip arthroplasty have had excellent results, with failure rates typically less than 5% at up to 10-year follow-up. Tritanium is a 3-dimensional metal interface that has been used for porous biological fixation. The purpose of this study was to review the clinical and radiographic results of the use of Tritanium cups (Stryker Orthopaedics, Mahwah, New Jersey) for primary total hip arthroplasty. Two hundred eighty-eight total hip arthroplasties performed using a porous titanium acetabular cup in 252 patients between 2008 and 2010 were reviewed. One hundred thirty-three men and 119 women with a mean age of 58 years (range, 18-88 years) were included. Mean follow-up was 36 months (range, 24-56 months). Outcomes evaluated were implant survivorship, Harris Hip Score, complications, and radiographic outcomes. At final follow-up, no cup failures had occurred. Mean Harris Hip Score improved from 53 points (range, 33-82 points) preoperatively to 91 points (range, 64-100 points) postoperatively. One complication occurred; a 64-year-old woman with recurrent postoperative effusions underwent hip exploration and required abductor mechanism repair. On radiologic evaluation, no signs existed of progressive radiolucencies or changes in cup position. The survivorship of the Tritanium cup and the low complication rate is comparable with previous studies using other porous-metal prostheses. Longer follow-up study is needed and assessment of the results of using this implant in the revision setting is important.
منابع مشابه
Short femoral stem and porous titanium: winning combination?
A lot of different implants are available in hip replacement arthroplasty (THA), stems differ mainly by type of fixation, material, length, diameter, shape, surface coating, modularity, etc. The main quality of a non-cemented stem is to pursuit primary and secondary stability, to preserve bone stock, to be adaptable and modular. The literature shows that the most popular non cemented stems used...
متن کاملSynthesis and Characterization of Highly Porous TiO2 Scaffolds for Bone Defects
The purpose of this study was to fabricate and investigate the highly porous structure using titanium dioxide, which is a candidate for bone defect repairing. For this purpose, TiO2 scaffolds were synthesized using titanium butoxide, Pluronic F127 surfactant, and polyurethane foam blocks. Therefore, a colloid includes titanium butoxide and F127 and the polyurethane foams were immersed in it. Th...
متن کاملFinite Element Analysis Stress Distribution Acetabular Cup Biomaterial FINITE ELEMENT ANALYSIS OF PERI-ACETABULAR STRESS OF CEMENTED, METAL-BACKED, AND POROUS TANTALUM BACKED ACETABULAR COMPONENTS
Introduction: In contemporary THA there are two broad approaches to acetabular cup design and materials. One is an all-polyethylene design with polymethylmethacrylate (PMMA) cement. PMMA possesses a modulus of elasticity of about 2 GPa, which is between that of trabecular and subchondral bone. The second more popular approach, especially for active, younger patients, is the porous metal-backed ...
متن کاملMigration pattern of cementless press fit cups in the presence of stabilizing screws in total hip arthroplasty
The aim of this study was to evaluate the initial acetabular implant stability and late acetabular implant migration in press fit cups combined with screw fixation of the acetabular component in order to answer the question whether screws are necessary for the fixation of the acetabular component in cementless primary total hip arthroplasty. One hundred and seven hips were available for follow-...
متن کامل10-year results of the uncemented Allofit press-fit cup in young patients
BACKGROUND AND PURPOSE Uncemented acetabular components in primary total hip arthroplasty (THA) are commonly used today, but few studies have evaluated their survival into the second decade in young and active patients. We report on a minimum 10-year follow-up of an uncemented press-fit acetabular component that is still in clinical use. METHODS We examined the clinical and radiographic resul...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orthopedics
دوره 36 4 شماره
صفحات -
تاریخ انتشار 2013