Motor thresholds in humans: a transcranial magnetic stimulation study comparing different pulse waveforms, current directions and stimulator types.
نویسندگان
چکیده
OBJECTIVES To evaluate the stimulation effectiveness of different magnetic stimulator devices with respect to pulse waveform and current direction in the motor cortex. METHODS In 8 normal subjects we determined motor thresholds of transcranial magnetic stimulation in a small hand muscle. We used focal figure-of-eight coils of 3 common stimulators (Dantec Magpro, Magstim 200 and Magstim Rapid) and systematically varied current direction (postero-anterior versus antero-posterior, perpendicular to the central sulcus) as well as pulse waveform (monophasic versus biphasic). The coil position was kept constant with a stereotactic positioning device. RESULTS Motor thresholds varied consistently with changing stimulus parameters, despite substantial interindividual variability. By normalizing the values with respect to the square root of the energy of the capacitors in the different stimulators, we found a homogeneous pattern of threshold variations. The normalized Magstim threshold values were consistently higher than the normalized Dantec thresholds by a factor of 1.3. For both stimulator types the monophasic pulse was more effective if the current passed the motor cortex in a postero-anterior direction rather than antero-posterior. In contrast, the biphasic pulse was weaker with the first upstroke in the postero-anterior direction. We calculated mean factors for transforming the intensity values of a particular configuration into that of another configuration by normalizing the different threshold values of each individual subject to his lowest threshold value. CONCLUSIONS Our transformation factors allow us to compare stimulation intensities from studies using different devices and pulse forms. The effectiveness of stimulation as a function of waveform and current direction follows the same pattern as in a peripheral nerve preparation (J Physiol (Lond) 513 (1998) 571).
منابع مشابه
Determining which mechanisms lead to activation in the motor cortex: a modeling study of transcranial magnetic stimulation using realistic stimulus waveforms and sulcal geometry.
OBJECTIVE To determine which mechanisms lead to activation of neurons in the motor cortex during transcranial magnetic stimulation (TMS) with different current directions and pulse waveforms. METHODS The total electric field induced in a simplified model of a cortical sulcus by a figure-eight coil was calculated using the finite element method (FEM). This electric field was then used as the i...
متن کاملDramatic Response of Resistant Obsessive Compulsive Disorder to Repeated Transcranial Magnetic Stimulation on Right Supplementary Motor Area
The response rate to the treatment of obsessive compulsive disorder (OCD) is 21.6% to 61.3%, which shows a relative resistance to current treatments and a need for novel therapeutic approaches. Here we report a case of resistant OCD with fast and dramatic response to a relatively new method of repeated transcranial magnetic stimulation. In this method a pulse magnetic field emits from a coil o...
متن کاملNon-Invasive Brain Stimulation for Enhancement of Corticospinal Excitability and Motor Performance
During the past .. years, non-invasive .rain stimulation has .ecome an emerging .eld in clinical neuroscience due to its capability to transiently modulate corticospinal excitability, motor and cognitive functions. .hereas transcranial magnetic stimulation has .een used e.tensively since more than t.o decades ago as a potential .neuromodulator., transcranial current stimulation .tCS. has more r...
متن کاملReliability of Motor Evoked Potentials Induced by Transcranial Magnetic Stimulation: The Effects of Initial Motor Evoked Potentials Removal
Introduction: Transcranial magnetic stimulation (TMS) is a useful tool for assessment of corticospinal excitability (CSE) changes in both healthy individuals and patients with brain disorders. The usefulness of TMS-elicited motor evoked potentials (MEPs) for the assessment of CSE in a clinical context depends on their intra-and inter-session reliability. This study aimed to evaluate if removal ...
متن کاملEffects of subthalamic nucleus (STN) stimulation on motor cortex excitability.
BACKGROUND Deep brain stimulation of the internal global pallidus (GPi) and the subthalamic nucleus (STN) has become a treatment alternative in advanced PD. Although the effects of GPi stimulation have been examined recently, little is known about STN stimulation effects on motor cortex excitability. METHODS The effects of STN stimulation were studied in eight patients with advanced PD using ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology
دوره 112 2 شماره
صفحات -
تاریخ انتشار 2001