Use of the Arndt wire-guided endobronchial blocker to facilitate one-lung ventilation for pediatric empyema during video-assisted thoracoscopy.

نویسندگان

  • Angie C Y Ho
  • Chun-Yu Chen
  • Min-Wen Yang
  • Hung-Pin Liu
چکیده

BACKGROUND Video-assisted thoracoscopic surgery (VATS) has emerged as an innovative and popular procedure for the management of postpneumonic empyema in children refractory to a medical response. One-lung ventilation is required during VATS. In this study, we evaluated the efficacy of intraoperative wire-guided endobronchial blockade (WEB) for achieving 1-lung ventilation during a thoracoscopic procedure for pediatric empyema. METHODS Eighteen patients undergoing a VATS approach for evacuation of an empyema cavity were studied. We used a new device, a bronchial blocker tube, to establish 1-lung ventilation. Intraoperative oxygenation, ventilation, and hemodynamics, as well as the duration of the operation during 1-lung ventilation were recorded. The number of unsuccessful placement attempts, number of malpositionings of the device, and the number of secondary dislodgements of the device after turning the patient into the lateral position were also counted. The quality of lung deflation and inflation was rated by the surgeon under direct visualization as either excellent, fair, or poor. RESULTS The mean operative time was 80+/-10.8 (range, 50 approximately 120) min. The mean peak inspiratory pressure under 1-lung ventilation was 28.7+/-3.6 cm H2O, and no desaturation was noted. A number of unsuccessful placement attempts were required in 1 patient (1/18) for left-sided VATS. No malpositioning or secondary dislodgement of the device was noted. The quality of lung deflation was judged as being excellent in all patients. CONCLUSIONS VATS can safely and effectively be performed in children with a proper anesthetic technique. With the development and clinical use of this new device, the bronchial blocker tube proved to be effective and easy to use for establishing 1-lung ventilation in a pediatric population.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of the Arndt wire-guided endobronchial blocker via nasal for one-lung ventilation in patient with anticipated restricted mouth opening for esophagectomy.

Functional separation of the lungs may be accomplished by several methods. Patient with restricted mouth opening has limited options for one-lung ventilation. We report the use of wire-guided endobronchial blockade, a new tool for achieving one-lung ventilation in a patient with restricted mouth opening requiring nasotracheal, fiberoptic intubation for esophagectomy and reconstruction with gast...

متن کامل

One lung ventilation for children with Pierre Robin sequence using SupremeTM LMA and Arndt endobronchial blocker: a case report

One lung ventilation (OLV) is a technique routinely used in thoracic anesthesia to facilitate thoracic surgery. We describe a case of pediatric with Pierre Robin sequence using SupremeTM laryngeal mask airway (LMA) and Arndt endobronchial blocker to achieve OLV.

متن کامل

An update on bronchial blockers during lung separation techniques in adults.

Techniques for one-lung ventilation (OLV) can be accomplished in two ways: The first involves the use of a double-lumen endotracheal tube (DLT). The second involves blockade of a mainstem bronchus (bronchial blockers). Bronchial blockade technology is on the rise, and in some specific clinical situations (e.g., management of the difficult airway during OLV or selective lobar blockade) it can of...

متن کامل

Extraluminal use of the Arndt pediatric endobronchial blocker in an infant: a case report.

PURPOSE Attaining lung isolation in the infant undergoing thoracic anesthesia can be challenging for the anesthesiologist. We describe a novel approach to performing lung isolation in an infant undergoing thoracotomy for lobectomy using an Arndt pediatric endobronchial blocker via an extraluminal technique. CLINICAL FEATURES Lung isolation in an infant was achieved through the use of an Arndt...

متن کامل

One-Lung Ventilation in a Patient with a Fresh Tracheostomy – A Case Report

After drainage of cervical abscesses, the tracheostomy was performed. For one-lung ventilation a wire guided endobronchial blocker (Arndt Blocker) was electively placed through the cannula of the fresh tracheostomy. The patient was submitted to one lung ventilation for 5 hours. Some episodes of hypoxemia required intermittent two lungs ventilation under 100% FiO2. The surgery lasted eight hours...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Chang Gung medical journal

دوره 28 2  شماره 

صفحات  -

تاریخ انتشار 2005