Analyzing LC-MS/MS data by spectral count and ion abundance: two case studies.
نویسندگان
چکیده
In comparative proteomics studies, LC-MS/MS data is generally quantified using one or both of two measures: the spectral count, derived from the identification of MS/MS spectra, or some measure of ion abundance derived from the LC-MS data. Here we contrast the performance of these measures and show that ion abundance is the more sensitive. We also examine how the conclusions of a comparative analysis are influenced by the manner in which the LC-MS/MS data is 'rolled up' to the protein level, and show that divergent conclusions obtained using different rollups can be informative. Our analysis is based on two publicly available reference data sets, BIATECH-54 and CPTAC, which were developed for the purpose of assessing methods used in label-free differential proteomic studies. We find that the use of the ion abundance measure reveals properties of both data sets not readily apparent using the spectral count.
منابع مشابه
Detecting differential and correlated protein expression in label-free shotgun proteomics.
Recent studies have revealed a relationship between protein abundance and sampling statistics, such as sequence coverage, peptide count, and spectral count, in label-free liquid chromatography-tandem mass spectrometry (LC-MS/MS) shotgun proteomics. The use of sampling statistics offers a promising method of measuring relative protein abundance and detecting differentially expressed or coexpress...
متن کاملSystematic Assessment of Survey Scan and MS2-Based Abundance Strategies for Label-Free Quantitative Proteomics Using High-Resolution MS Data
Survey-scan-based label-free method have shown no compelling benefit over fragment ion (MS2)-based approaches when low-resolution mass spectrometry (MS) was used, the growing prevalence of high-resolution analyzers may have changed the game. This necessitates an updated, comparative investigation of these approaches for data acquired by high-resolution MS. Here, we compared survey scan-based (i...
متن کاملCysteinyl Peptide Capture for Shotgun Proteomics: Global Assessment of Chemoselective Fractionation
The complexity of cell and tissue proteomes presents one of the most significant technical challenges in proteomic biomarker discovery. Multidimensional liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based shotgun proteomics can be coupled with selective enrichment of cysteinyl peptides (Cys-peptides) to reduce sample complexity and increase proteome coverage. Here we evaluated the i...
متن کاملComparison of Traditional 2-AB Fluorescence LC-MS/MS and Automated LC-MS for the Comparative Glycan Analysis of Monoclonal Antibodies.
Monoclonal antibody therapeutics are a heterogeneous mixture of glycoforms. Multiple methods exist for defining the glycan composition and relative abundance of species present. In the current report, two MS-based methods were compared for their ability to both identify glycans and monitor differences in the glycoprofile. Gross changes in the glycoprofile can be identified either by visual insp...
متن کاملEnhanced detection of low abundance human plasma proteins using a tandem IgY12-SuperMix immunoaffinity separation strategy.
The enormous dynamic range of human bodily fluid proteomes poses a significant challenge for current MS-based proteomics technologies as it makes it especially difficult to detect low abundance proteins in human biofluids such as blood plasma, which is an essential aspect for successful biomarker discovery efforts. Here we present a novel tandem IgY12-SuperMix immunoaffinity separation system f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Statistics and its interface
دوره 5 1 شماره
صفحات -
تاریخ انتشار 2012