Three-dimensional seed reconstruction from an incomplete data set for prostate brachytherapy.

نویسندگان

  • Sreeram Narayanan
  • Paul S Cho
  • Robert J Marks
چکیده

Intra-operative dosimetry in prostate brachytherapy requires 3D coordinates of the implanted, radioactive seeds. Since CT is not readily available during the implant operation, projection x-rays are commonly used for intra-operative seed localization. Three x-ray projections are usually used. The requirement of the current seed reconstruction algorithms is that the seeds must be identified on all three projections. However, in practice this is often difficult to accomplish due to the problem of heavily clustered and overlapping seeds. We have developed an algorithm that permits seed reconstruction from an incomplete data set. Instead of all three projections, the new algorithm requires only one of the three projections to be complete. Furthermore, even if all three projections are incomplete, it can reconstruct 100% of the implanted seeds depending on how the undetected seeds are distributed among the projections. The method utilizes the principles of epipolar imaging geometry and pseudo-matching of the undetected seeds. The algorithm was successfully applied to a large number of clinical cases where seeds imperceptibly overlap in some projections.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional seed reconstruction for prostate brachytherapy using Hough trajectories.

In order to perform intra-operative or post-implant dosimetry in prostate brachytherapy, the 3D coordinates of the implanted radioactive seeds must be determined. Film or fluoroscopy based seed reconstruction techniques use back projection of x-ray data obtained at two or three x-ray positions. These methods, however, do not perform well when some of the seed images are undetected. To overcome ...

متن کامل

Brachytherapy seed reconstruction with joint-encoded C-arm single-axis rotation and motion compensation

C-arm fluoroscopy images are frequently used for qualitative assessment of prostate brachytherapy. Three-dimensional seed reconstruction from C-arm images is necessary for intraoperative dosimetry and quantitative assessment. Seed reconstruction requires accurately known C-arm poses. We propose to measure the C-arm rotation angles and computationally compensate for inevitable C-arm motion to co...

متن کامل

Intraoperative 3D reconstruction of prostate brachytherapy implants with automatic pose correction.

The success of prostate brachytherapy critically depends on delivering adequate dose to the prostate gland, and the capability of intraoperatively localizing implanted seeds provides potential for dose evaluation and optimization during therapy. REDMAPS is a recently reported algorithm that carries out seed localization by detecting, matching and reconstructing seeds in only a few seconds from ...

متن کامل

Matching and reconstruction of brachytherapy seeds using the Hungarian algorithm (MARSHAL).

Intraoperative dosimetric quality assurance in prostate brachytherapy critically depends on discerning the three-dimensional (3D) locations of implanted seeds. The ability to reconstruct the implanted seeds intraoperatively will allow us to make immediate provisions for dosimetric deviations from the optimal implant plan. A method for seed reconstruction from segmented C-arm fluoroscopy images ...

متن کامل

Detection and correction of patient movement in prostate brachytherapy seed reconstruction.

Intraoperative dosimetry of prostate brachytherapy can help optimize the dose distribution and potentially improve clinical outcome. Evaluation of dose distribution during the seed implant procedure requires the knowledge of 3D seed coordinates. Fluoroscopy-based seed localization is a viable option. From three x-ray projections obtained at different gantry angles, 3D seed positions can be dete...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 49 15  شماره 

صفحات  -

تاریخ انتشار 2004