Automatic semi-microcolumn liquid chromatographic determination of catecholamines in rat plasma utilizing peroxyoxalate chemiluminescence reaction.
نویسندگان
چکیده
A fully automated and highly sensitive method with a semi-microcolumn liquid chromatography system for the determination of rat plasma catecholamines (CAs) was developed. Automated on-line extraction of CAs in diluted plasma using a precolumn packed with strong acidic cation exchange resin was coupled with separation of CAs on a semi-microcolumn (250 x 1.5 mm id). fluorogenic derivatization with ethylenediamine and finally postcolumn peroxyoxalate chemiluminescence detection utilizing bis[2-(3,6,9-trioxadecanyloxycarbonyl)-4-nitrophenyl]oxalate (TDPO) and hydrogen peroxide. The detection limits were 0.91, 0.36 and 1.1 fmol for norepinephrine (noradrenaline), epinephrine (adrenaline) and dopamine, respectively, at a signal-to-noise ratio of 3. A good linearity of the calibration curve for each CA was observed in the range of 5.0 to 500 fmol for each CA using N-methyldopamine (N-MeDA) as an internal standard. The RSD for the proposed method (n = 5) were 3.7-9.5% for the intra-day assay and 6.6-10.0% for the inter-day assay. The volume of rat plasma required for the determination of CAs was 10 microliters.
منابع مشابه
Selective determination of doxorubicin and doxorubicinol in rat plasma by HPLC with photosensitization reaction followed by chemiluminescence detection.
A highly sensitive and selective high-performance liquid chromatography (HPLC) method was developed for the determination of doxorubicin (DXR) and its metabolite doxorubicinol (DXR-ol) in rat plasma. The method was based on photosensitization reaction followed by peroxyoxalate chemiluminescence detection (PO-CL). DXR and DXR-ol that were fluorescent quinones, served as a photosensitizer in the ...
متن کاملIndirect chemiluminescence-based determination of catecholamines in pharmaceutical formulations by furandicarboxylate derivative as a novel blue fluorescer in peroxyoxalate-H₂O₂ system.
A novel, simple, cheap, and high sensitivity batch chemiluminescent method for the determination of catecholamine drugs, epinephrine (E), dopamine (DA) and methyldopa (MD) at microgram levels in pharmaceutical formulations is described. The method is based on a chemiluminescence (CL) system arising from the reaction of bis(2,4,6-trichlorophenyl) oxalate (TCPO) with H₂O₂ in the presence of a nov...
متن کاملHPLC determination of methylphenidate and its metabolite, ritalinic acid, by high-performance liquid chromatography with peroxyoxalate chemiluminescence detection.
An HPLC-peroxyoxalate chemiluminescence (PO-CL) method for simultaneous determination of methylphenidate (MPH) and ritalinic acid (RA) was developed. The method was used to monitor MPH and RA after administration of MPH to rats. Deproteinized plasma spiked with 1-(3-trifluoromethylphenyl)piperazine (IS) was dried and labeled with 4-(N,N-dimethylaminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole (DBD-...
متن کامل[Role of catecholamine metabolism in blood pressure regulation using chemiluminescence reaction detection].
Catecholamines, namely, dopamine, norepinephrine and epinephrine, play important roles in higher animals as neurotransmitters or hormones, and are metabolized by catechol-O-methyltransferase (COMT). To elucidate the role of COMT in blood pressure regulation, we have developed simultaneous determination methods for catecholamines and their 3-O-methyl metabolites using high-performance liquid chr...
متن کاملDetermination of C-21 ketosteroids in serum using trifluoromethanesulfonic acid catalyzed precolumn dansylation and 1,1'-oxalyldiimidazole postcolumn peroxyoxalate chemiluminescence detection.
A new procedure for the quantitation of C-21 ketosteroids using trifluoromethanesulfonic acid-catalyzed precolumn dansylation and coupled column liquid chromatographic separation, followed by postcolumn 1,1'-oxalyldiimidazole peroxyoxalate chemiluminescence detection is presented. In the simultaneous optimization of chromatographic resolution and chemiluminescence intensity, a coupled column ch...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Analyst
دوره 125 2 شماره
صفحات -
تاریخ انتشار 2000