Protocol for the Conconi test and determination of the heart rate deflection point.
نویسندگان
چکیده
Recently Ozcelik and Kelestimur (2004) have assessed the validity of the heart rate deflection point in the power output-heart rate relationship (Conconi test) for estimating the anaerobic threshold in different experimental conditions (normoxia and hypoxia). In their study, the tests were performed with an electromagnetically braked cycle ergometer at constant cadence with increments in power output obtained by increasing the pedalling resistance. In cycle ergometry, modifications of the testing protocol give rise to modifications of neurohumoral and gas exchange responses (Gullestad et al. 1997), of power outputs at given respiratory exchange ratios (Amann et al. 2004) and modifications of the relationship between work rate, oxygen uptake and heart rate (Myers and Froelicher 1990). In this letter, we discuss the differences between the testing protocol used by Ozcelik and Kelestimur and the one developed by Conconi et al. (1996) and Grazzi et al. (1999). Three points of the testing procedure used by the authors will be particularly considered.
منابع مشابه
Validity of the modified conconi test for determining ventilatory threshold during on-water rowing.
The objectives of this study were to design a field test based on the Conconi protocol to determine the ventilatory threshold of rowers and to test its reliability and validity. A group of sixteen oarsmen completed a modified Conconi test for on-water rowing. The reliability of the detection of the heart rate threshold was evaluated using heart rate breaking point in the Conconi test and retest...
متن کاملValidity of the heart rate deflection point as a predictor of lactate threshold during running.
During an incremental run test, some researchers consistently observe a heart rate (HR) deflection at higher speeds, but others do not. The present study was designed to investigate whether differences in test protocols could explain the discrepancy. Additionally, we sought to determine whether the HR deflection point accurately predicts lactate threshold (LT). Eight trained runners performed f...
متن کاملComparison of ventilation threshold and heart rate deflection point in fast and standard treadmill test protocols.
The purpose of this study was to compare two methods for determination of anaerobic threshold from two different treadmill protocols. Forty-eight Croatian runners of national rank (ten sprinters, fifteen 400-m runners, ten middle distance runners and thirteen long distance runners), mean age 21.7 +/- 5.1 years, participated in the study. They performed two graded maximal exercise tests on a tre...
متن کاملValue of the application of the heart rate performance curve in sports.
The heart rate performance curve (HRPC) has been shown to be nonlinearly related to work load. This phenomenon has been used to determine a deflection point and to be related to the lactate anaerobic threshold. The original method was heavily criticized, and the method was challenged by several authors. However, some authors also demonstrated a high value for this method's application in variou...
متن کاملEffects of acute hypoxia on the determination of anaerobic threshold using the heart rate-work rate relationships during incremental exercise tests.
Anaerobic threshold which describes the onset of systematic increase in blood lactate concentration is a widely used concept in clinical and sports medicine. A deflection point between heart rate-work rate has been introduced to determine the anaerobic threshold non-invasively. However, some researchers have consistently reported a heart rate deflection at higher work rates, while others have n...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physiological research
دوره 54 4 شماره
صفحات -
تاریخ انتشار 2005