Shear Wave Elastography In Characterization Of Liver Tumours

نویسندگان

  • K. L. Choong
  • B. J. J. Abdullah
  • G. Kumar
  • C. H. Yeong
  • K. L. Goh
  • B. K. Yoong
چکیده

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Shear wave elastography with a new reliability indicator

Non-invasive methods for liver stiffness assessment have been introduced over recent years. Of these, two main methods for estimating liver fibrosis using ultrasound elastography have become established in clinical practice: shear wave elastography and quasi-static or strain elastography. Shear waves are waves with a motion perpendicular (lateral) to the direction of the generating force. Shear...

متن کامل

Fibroscan (transient elastography) for the measurement of liver fibrosis.

NHA The Fibroscan device (Echosens) works by measuring shear wave velocity. In this technique, a 50-MHz wave is passed into the liver from a small transducer on the end of an ultrasound probe (Figure 1). The probe also has a transducer on the end that can measure the velocity of the shear wave (in meters per second) as this wave passes through the liver. The shear wave velocity can then be conv...

متن کامل

Reproducibility of shear wave elastography (SWE) in patients with chronic liver disease

The presence of significant fibrosis is an indicator for liver disease staging and prognosis. The aim of the study was to determine reproducibility of real-time shear wave elastography using a hepatic biopsy as the reference standard to identify patients with chronic liver disease. Forty patients with chronic liver disease and 12 normal subjects received shear wave elastography performed by ski...

متن کامل

Is shear viscosity a sign for malignancy in liver tumours?

Introduction Liver tumours are very frequent. They include benign lesions and malignant primary or secondary tumours (metastases). About 1 million people die each year from liver cancer or liver failure caused by viral hepatitis. The liver is also a frequent site of metastases. Currently, there is no established non-invasive imaging Goldstandard available in order to characterize malignancy for...

متن کامل

Sonoelastography in the musculoskeletal system: Current role and future directions

Ultrasound is an essential modality within musculoskeletal imaging, with the recent addition of elastography. The elastic properties of tissues are different from the acoustic impedance used to create B mode imaging and the flow properties used within Doppler imaging, hence elastography provides a different form of tissue assessment. The current role of ultrasound elastography in the musculoske...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014