Modeling and simulation of deadbeat-based PI controller in a single-phase H-bridge inverter for stand-alone applications

نویسندگان

  • Tow Leong TIANG
  • Dahaman ISHAK
چکیده

This paper presents a deadbeat-based proportional-integral (PI) controller for a stand-alone single-phase voltage source inverter using a battery cell as the primary energy source. The inverter system is simulated in MATLAB/Simulink. It consists of a lead acid battery, third-order Butterworth low-pass DC filter and AC filter, H-bridge inverter, step-up transformer, and a variety of loads, as well as its sinusoidal pulse-width modulation (SPWM) deadbeatbased PI controller. In this paper, 2 simulation case studies are carried out, which are the abrupt load changes from a 400 W resistive load to a 500 W resistive load, and from a 400 W resistive load to an inductive load of 500 W 0.85 power factor lagging. From the simulation results for both cases, the state-of-charge of the battery decreases due to supplying power to the loads, yet the battery voltage remains constant at about 36 V and the battery current exhibits a smooth ripple despite the current spikes produced by the H-bridge inverter, which will prolong the lifespan of the battery. This shows that the DC filter performs satisfactorily to isolate the current spikes generated by the SPWM controller and H-bridge inverter. Moreover, even though the load varies for both cases, the sinusoidal inverter output voltage can be tracked and maintained at 230 Vrms with a 50 Hz frequency within a few cycles from the instant that the load is changed, as well as a low total harmonic distortion voltage (THDv) content of 1.53% and 2.78%, respectively. This indicates that the controller proves its robustness and stiffness characteristics in maintaining the output load voltage at the desired value to supply the power for a variety of loads with a minimum THDv .

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Stand-Alone Single-Phase Induction Generator Using a Three-Phase Machine and a Single-Phase PWM Inverter

A new type of single-phase stand-alone induction generator using a three-phase induction machine and a single-phase voltage-source PWM inverter is introduced. The generator scheme is capable of producing constant load frequency with a very well regulated output voltage. A small lead acid battery and a single-phase full diode-bridge rectifier are used to feed the inverter. The inverter feeds one...

متن کامل

A New Approach for Reactive Power Control of Single Phase Transformerless Inverter to Modify Power Quality in Stand Alone Micro-Grids with Current Leakage Elimination

Nowadays there has been an increasing interest in transformerless inverter for grid-connected photovoltaic (PV) system due to low cost, high efficiency and light weight. One of the reasons describe the grid behavior is capability of reactive power control by inverter. According to the standard VDE-AR-N 4105, grid-tied PV inverter of power rating below 3.68KVA, should attain power factor (PF) fr...

متن کامل

A Novel Controller Based on Single-Phase Instantaneous p-q Power Theory for a Cascaded PWM Transformer-less STATCOM for Voltage Regulation

In this paper, dynamic performance of a transformerless cascaded PWM static synchronous shunt compensator (STATCOM) based on a novel control scheme is investigated for bus voltage regulation in a 6.6kV distribution system. The transformerless STATCOM consists of a thirteen-level cascaded H-bridge inverter, in which each voltage source H-bridge inverter should be equipped with a floating and iso...

متن کامل

Transformer-based Single-source Multilevel Inverter with Reduction in Number of Transformers

Single-source binary hybrid multilevel inverters with cascaded transformers have a bulky transformer connected to their main H-bridge cells in each phase. This bulky transformer has been eliminated in this work without any effect on operation and modulation strategies. The proposed topology has significant advantages from view point of dimensions and number of transformers, design of transforme...

متن کامل

Simulation and Comparison of Twenty Five Level Diode Clamped & Cascaded H-Bridge Multilevel Inverter

This paper presents the comparative study of three phase twenty five level diode clamped and cascaded H-bridge multilevel inverters. The comparison is made in respect of requirement of devices, quality of output voltage and reduction of total harmonic distortion at the multilevel inverter terminals. In this work multicarrier sinusoidal pulse modulation control methods of Phase disposition (PD-P...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013