Cataract surgeries by phaco-sandwich technique through sclerocorneal tunnel, a cohort study in Oman.

نویسندگان

  • Mohammad Naqaish Sadiq
  • Anant Pai
  • Padma Mohan J Kurup
چکیده

BACKGROUND To evaluate the changes in Preoperative and Postoperative keratometry results and rapid visual rehabilitation in Cataract surgery by our phaco-sandwich technique through the self sealing sclero-corneal tunnel incision without phacoemulsification. METHODS 96 eyes of 88 patients with age-related cataracts underwent small incision suture less cataract surgery without phacoemulsification. All eyes were operated by the phaco-sandwich technique through sclerocorneal tunnel with 6 mm frown-shaped external scleral incision. 6 mm single piece PMMA lens was implanted in the capsular bag. Patients were evaluated at 1 week, 4 weeks and 12 weeks post-operatively. RESULTS Ninety six eyes of eighty eight patients were our cohort. During the first post-operative week 8 eyes (8.3%) had uncorrected visual acuity (UCVA) of 6/6. By the end of 12 post-operative weeks, 33 eyes (34.5%) had UCVA of 6/6. 64 (66.7%), 72 (75%) and 80 (83.3%) eyes had best correctable visual acuity (BCVA) of 6/6 after 4 weeks, 8 weeks and 12 weeks respectively. 64 (66.7%) eyes after 4 weeks, 72 (75%) after 8 weeks and 80 (83%) after 12 weeks had best correctable visual acuity (BCVA) of 6/6. CONCLUSION Suture less, small-incision cataract surgery is an economical, safe and effective method of managing cataract cases. This technique also ensures satisfactory and rapid rehabilitation for patients. This procedure can be effectively applied to clear the backlog of cataract-related blindness in places wherein the resources for phaco facilities are not available.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuring phacoemulsification groove depth using probe tip dimensions and biometry lens thickness readings

AIM To describe a useful technique utilizing lens thickness from biometric data as well as phacoemulsification (phaco) probe tip dimensions, in order to more accurately determine safe groove depth during divide and conquer techniques for cataract surgery. METHODS Single center, selection of patients for cataract surgery deemed low risk and suitable for surgical teaching cases. Individual lens...

متن کامل

Outcome of phacoemulsification and extracapsular cataract extraction: A study in a district hospital in Malaysia.

AIM The aim of the study was to compare the outcomes of phacoemulsification (Phaco) and extracapsular cataract extraction (ECCE) in a district hospital setting. METHODS A retrospective analysis was done from the medical records of the patients who underwent Phaco and ECCE in Temerloh District Hospital, Pahang state between October 2009 and September 2010. The age, gender and ethnicity of the ...

متن کامل

Non phaco suture less cataract extraction through temporal approach.

BACKGROUND Non Phaco suture less cataract extraction through temporal approach retains most of the advantages of phacoemulsification but can be delivered at lower cost with better visual out come. METHODS Extra capsular cataract extraction followed by posterior chamber intraocular lens implantation was performed, on 300 eyes of 250 patients. The technique involved was posterior limbal corneal...

متن کامل

A retrospective randomized study to compare the energy delivered using CDE with different techniques and OZil® settings by different surgeons in phacoemulsification

Cumulative dissipated energy (CDE) was used with Infiniti((R)) Vision System (Alcon Labs) as an energy delivery guide to compare four different phaco techniques and phaco settings. The supracapsular phaco technique and burst mode is known for efficiency and surgery is faster compared with the old phaco unit. In this study, we found that supracapsular phaco with burst mode had the least CDE in b...

متن کامل

Usefulness of Surgical Media Center as a Cataract Surgery Educational Tool.

Purpose. This study retrospectively analyzed cataract surgeries to examine the usefulness of Surgical Media Center (SMC) (Abbott Medical Optics Inc.), a new cataract surgery recording device, for training of cataract surgery. Methods. We studied five hundred cataract surgeries conducted with a phacoemulsification system connected to the SMC. After surgery, the surgical procedures were reviewed,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Ayub Medical College, Abbottabad : JAMC

دوره 18 4  شماره 

صفحات  -

تاریخ انتشار 2006