A Digital System For Surface Reconstruction
نویسندگان
چکیده
A digital photogrammetric system, STEREO, was developed to determine three dimensional coordinates of points of interest (POIs) defined with a grid on a textureless and smooth-surfaced specimen. Two CCD cameras were set up with unknown orientation and recorded digital images of a reference model and a specimen. Points on the model were selected as control or check points for calibrating or assessing the system. A new algorithm for edge-detection called local maximum convolution (LMC) helped extract the POIs from the stereo image pairs. The system then matched the extracted POIs and used a least squares “bundle” adjustment procedure to solve for the camera orientation parameters and the coordinates of the POIs. An experiment with STEREO found that the standard deviation of the residuals at the check points was approximately 24%, 49% and 56% of the pixel size in the X, Y and Z directions, respectively. The average of the absolute values of the residuals at the check points was approximately 19%, 36% and 49% of the pixel size in the X, Y and Z directions, respectively. With the graphical user interface, STEREO demonstrated a high degree of automation and its operation does not require special knowledge of photogrammetry, computers or image processing. A DIGITAL SYSTEM FOR SURFACE RECONSTRUCTION 2 Introduction To meet the needs of mechanics experiments, a linear image strain analysis (LISA) system was developed (Choi et al., 1991). This system measures the deformation of a specimen in two dimensions with high accuracy. Many experiments have been carried out with this system on various paper specimens. But, with LISA, the deformation of the specimen in the out-of-plane direction cannot be measured. A project started in 1991 to develop a system for reconstructing surfaces in three dimensions. Zhou et al. (1992) reported on the early results of this project. Since then, the system, now called STEREO, has been changed and improved substantially. This paper outlines the implementation of STEREO and the results of experiments with this system. STEREO has to meet several requirements imposed by mechanical experiments. First, the system needs to satisfy many experimental conditions and yield results speedily with little operator intervention. This requirement excludes the use of traditional photogrammetry, which often requires excessive time combined with particular skills and equipment. Second, the system should be accurate relative to its hardware limitations. The sensitive recording part of a CCD (charge coupled device) camera is a chip with an array of micro-sensors, each corresponding to a pixel in the output image. SL and SW, a CCD camera’s ability to measure coordinates in the image plane in the length and width directions, respectively, can be calculated:
منابع مشابه
Design and Manipulation 3D Imaging System by using Photodiode Grid
Introduction: Radiation imaging is one of the applicable methods in diagnostic medicine and nondestructive testing for industrial applications. In nondestructive 3D imaging, in addition to the radiation source, there is a requirement for a suitable detection system, data acquisition system, mechanical sections for moving objects, reconstruction algorithm and finally a computer for processing an...
متن کاملReconstruction of long digital extensor tendon by cranial tibial muscle fascia graft in a dog
Tendon rupture in dogs is generally the result of a direct trauma. This report described the use of adjacent muscle autogenic fascial graft for reconstruction of distal rupture of long digital extensor tendon in a dog. A two-year-old male mix breed dog, was presented with a non-weight bearing lameness of the right hind limb and a deep rupture of lateral side of right tarsus. History taking reve...
متن کاملمحاسبۀ تابع انتقال مدولاسیون برای بررسی کنترل کیفی در رادیولوژی دیجیتال
The usage of digital radiology systems with insufficient quality control of digital image detectors can efface inherent superiorities of digital systems in comparison with analogue radiology systems and even makes an increased level of patients’ radiation doses. Modulation transfer function (MTF) is one of the most important parameters related to image quality and digital detectors efficiency. ...
متن کاملAccuracy of an Intraoral Digital System for File Length Measurement
Introdouction: Canal length measurement is essential for proper endodontic treatment. Any error or miscalculation in working length determination, particularly in curved canals, can result in complications during or after root canal therapy. Digital radiography has enabled accurate measurement of curved canal length. In this study, we evaluated the accuracy of calibration of a complementary m...
متن کاملSurface reconstruction of detect contours for medical image registration purpose
Although, most of the abnormal structures of human brain do not alter the shape of outer envelope of brain (surface), some abnormalities can deform the surface extensively. However, this may be a major problem in a surface-based registration technique, since two nearly identical surfaces are required for surface fitting process. A type of verification known as the circularity check for th...
متن کاملThe Practice of Chest Radiography Using Different Digital Imaging Systems: Dose and Image Quality
Introduction: The study was undertaken to evaluate the practice of chest radiography using different digital imaging systems and its influence on dose and image quality. Materials and Methods: The study was carried out in two hospitals from March 2016 to June 2016. Sixty ambulatory patients aged 21 to 60 years who were able to cooperate without difficulty and weighed between 60 to 80 kg were ...
متن کامل