Intraretinal segmentation on fourier domain optical coherence tomography.
نویسندگان
چکیده
INTRODUCTION We studied the automated intraretinal segmentation on Fourier domain optical coherence tomography (OCT). MATERIALS AND METHODS Thirty eyes from 30 normal subjects were studied using the RTVue-100. Both radial and raster scan protocol were performed 3 times on each subject. The OCT software performs automated intraretinal segmentation and provides macular thickness measurements. RESULTS Both scanning protocols provide reproducible inner, outer and full retinal thickness measurements. The inner, outer and full retinal thicknesses at the foveal central subfield were 67.31 +/- 12.27 microm, 151.67 +/- 12.96 microm, 219.33 +/- 23.19 microm, respectively by the raster scan, and 63.27 +/- 10.37 microm, 147.07 +/- 14.54 microm, 209.89 +/- 21.80 microm, respectively by the radial scan. Macular regional variations were consistently observed. The raster scan protocol gives greater retinal thickness measurements than the radial scan protocol (P <0.05), but the latter yields slightly more reproducible results. CONCLUSIONS Fourier domain OCT equipped with the ability to perform automatic intraretinal segmentation is a convenient tool in studying diseases that may differentially affect various parts of the retina. However, the establishment of normative values can be complicated by different scanning protocols, devices used, methods of data presentation and definition of intraretinal boundaries.
منابع مشابه
Comparison of retinal thickness by Fourier-domain optical coherence tomography and OCT retinal image analysis software segmentation analysis derived from Stratus optical coherence tomography images.
PURPOSE To compare thickness measurements between Fourier-domain optical coherence tomography (FD-OCT) and time-domain OCT images analyzed with a custom-built OCT retinal image analysis software (OCTRIMA). METHODS Macular mapping (MM) by StratusOCT and MM5 and MM6 scanning protocols by an RTVue-100 FD-OCT device are performed on 11 subjects with no retinal pathology. Retinal thickness (RT) an...
متن کاملMultivendor Spectral-Domain Optical Coherence Tomography Dataset, Observer Annotation Performance Evaluation, and Standardized Evaluation Framework for Intraretinal Cystoid Fluid Segmentation
Development of image analysis and machine learning methods for segmentation of clinically significant pathology in retinal spectral-domain optical coherence tomography (SD-OCT), used in disease detection and prediction, is limited due to the availability of expertly annotated reference data. Retinal segmentation methods use datasets that either are not publicly available, come from only one dev...
متن کاملاندازهگیری همزمان ضریب شکست و ضخامت فیزیکی دستگاههای چندلایهای با استفاده از نتایج مقطعنگاری همدوسی اپتیکی در فضای فوریه
In fourier domain optical coherence tomography, we can measure the optical thickness ( refractive index n times thickness d), to obtain the retinal layers in order to diagnose many disorders. In this work, we introduce a new method for measurement of refractive index and physical thickness of multiple layers simultaneously by Fourier domain optical coherence tomography, without additional infor...
متن کاملAutomated 3-D segmentation and analysis of retinal optical coherence tomography images
Optical coherence tomography (OCT) is becoming an increasingly important modality for the noninvasive assessment of a variety of ocular diseases such as glaucoma, diabetic macular edema, and age-related macular degeneration. Even though individual layers of the retina are visible on OCT images, current commercial quantitative assessment is limited to measuring the thickness of only one layer. B...
متن کاملRobust segmentation of intraretinal layers in the normal human fovea using a novel statistical model based on texture and shape analysis.
A novel statistical model based on texture and shape for fully automatic intraretinal layer segmentation of normal retinal tomograms obtained by a commercial 800nm optical coherence tomography (OCT) system is developed. While existing algorithms often fail dramatically due to strong speckle noise, non-optimal imaging conditions, shadows and other artefacts, the novel algorithm's accuracy only s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Annals of the Academy of Medicine, Singapore
دوره 39 7 شماره
صفحات -
تاریخ انتشار 2010