Intraocular Lens Power Calculation after Corneal Refractive Surgery

نویسندگان

  • Mohammad-Ali Javadi
  • Sepehr Feizi
  • Parviz Malekifar
چکیده

PURPOSE To determine the accuracy of a method of calculating intraocular lens (IOL) power after corneal refractive surgery. SETTING Department of Ophthalmology, Hospital de Gipuzkoa, San Sebastián, Spain. METHODS The SRK/T formula was modified to use the pre refractive surgery K-value (Kpre) for the effective lens position (ELP) calculation and the post refractive surgery K-value (Kpost) for IOL power calculation by the vergence formula. The Kpre value was obtained by keratometry or topography and the Kpost, by the clinical history method. The formula was assessed in 9 cases of cataract surgery after laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK) in which all relevant data were available. Refractive results of the standard SRK/T and the double-K SRK/T were compared statistically. RESULTS The mean IOL power for emmetropia and the achieved refraction (mean spherical equivalent [SE]), respectively, were +17.85 diopters (D) +/- 3.43 (SD) and +1.82 +/- 0.73 with the standard SRK/T and +20.25 +/- 3.55 D and +0.13 +/- 0.62 D with the double-K SRK/T. No case in the standard SRK/T group and 6 cases (66.66%) in the double-K group achieved a +/-0.5 D SE. CONCLUSION Double-K modification of the SRK/T formula improved the accuracy of IOL power calculation after LASIK and PRK.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraocular lens power calculatio n after corneal refractive surgery

Current Opinion in Ophthalmology 2008, 19:357–362 Purpose of review Corneal refractive procedures have become increasingly popular over the past decade allowing patients to have excellent uncorrected visual acuity and spectacle independence. As these individuals mature, many will eventually undergo cataract surgery. With the advances in modern cataract surgery and lens implant technology, parti...

متن کامل

[Intraocular lens power calculations in eyes with previous corneal refractive surgery].

Results of intraocular lens power calculation were lower than actual required power in eyes with previous corneal refractive surgery because the inaccurate readings of corneal power obtained from standard keratometry. This causes the unacceptable hyperopia after cataract surgery. With increasing of population undergone excimer laser refractive surgery, this problem will be an obvious problem in...

متن کامل

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Estimation of Intraocular Lens Power Calculation after Myopic Corneal Refractive Surgery: Using Corneal Height in Anterior Segment Optical Coherence Tomography

PURPOSE To investigate the feasibility of estimating effective lens position (ELP) and calculating intraocular lens power using corneal height (CH), as measured using anterior segment optical coherence tomography (AS-OCT), in patients who have undergone corneal refractive surgery. METHODS This study included 23 patients (30 eyes) who have undergone myopic corneal refractive surgery and subseq...

متن کامل

IOL Power Calculation after Corneal Refractive Surgery

PURPOSE To describe the different formulas that try to overcome the problem of calculating the intraocular lens (IOL) power in patients that underwent corneal refractive surgery (CRS). METHODS A Pubmed literature search review of all published articles, on keyword associated with IOL power calculation and corneal refractive surgery, as well as the reference lists of retrieved articles, was pe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2000