Determination of free haemoglobin in serum by an automated assay using 4-aminophenazone and the Cobas Bio System.
نویسنده
چکیده
A colorimetric method for the determination of free haemoglobin in human serum is described, using 4-aminophenazone as chromogen, and commercially available haemiglobin cyanide solutions as standards. The reaction system is suitable for manual measurements as well as determinations with a centrifugal analyser (Cobas Bio System). Accuracy, linearity and stability of the procedure is shown. A reference interval in sera of normal adults was established, with an upper limit of 5 mg/dl. The alternative use of heparin plasma instead of serum is discussed.
منابع مشابه
Kinetic enzymatic method for automated determination of HDL cholesterol in plasma.
A sensitive fixed-time kinetic enzymatic method for the measurement of high density lipoprotein cholesterol is described, as adapted for the Cobas Bio centrifugal analyser (Hoffmann LaRoche). The Boehringer Mannheim cholesterol esterase/cholesterol oxidase/peroxidase/3,4-dichlorophenol kinetic reagent was modified by the inclusion of 2,4,6-tribromo-3-hydroxybenzoic acid which reacts with hydrog...
متن کاملInterference-free Determination of Carbamazepine in Human Serum Using High Performance Liquid Chromatography: A Comprehensive Research with Three-way Calibration Methods
In the present study, a comprehensive and systematic strategy was described to evaluate the performance of several three-way calibration methods on a bio-analytical problem. Parallel factor analysis (PARAFAC), alternating trilinear decomposition (ATLD), self-weighted alternating trilinear decomposition (SWATLD), alternating penalty trilinear decomposition (APTLD) and unfolded partial least squa...
متن کاملInterference-free Determination of Carbamazepine in Human Serum Using High Performance Liquid Chromatography: A Comprehensive Research with Three-way Calibration Methods
In the present study, a comprehensive and systematic strategy was described to evaluate the performance of several three-way calibration methods on a bio-analytical problem. Parallel factor analysis (PARAFAC), alternating trilinear decomposition (ATLD), self-weighted alternating trilinear decomposition (SWATLD), alternating penalty trilinear decomposition (APTLD) and unfolded partial least squa...
متن کاملSecure Bio-Cryptographic Authentication System for Cardless Automated Teller Machines
Security is a vital issue in the usage of Automated Teller Machine (ATM) for cash, cashless and many off the counter banking transactions. Weaknesses in the use of ATM machine could not only lead to loss of customer’s data confidentiality and integrity but also breach in the verification of user’s authentication. Several challenges are associated with the use of ATM smart card such as: card clo...
متن کاملPerformance characteristics of three automated immunoassays for thyroid hormones
Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie
دوره 19 9 شماره
صفحات -
تاریخ انتشار 1981