High throughput clinical CMR service: role of technologists in LV volume analysis

نویسندگان

  • Elisa McAlindon
  • Chris Lawton
  • Cornelius Imobeke
  • Jessica Harris
  • Barney Reeves
  • Chiara Bucciarelli-Ducci
چکیده

Methods 20 CMR studies of acute coronary syndromes were included in this study. Analysis was conducted using Argus, Siemens semi-automated volume analysis software. 3 observers conducted the image analysis with two levels of training: Observer 1) “Reference” CMR level 3 physician; Observer 2) and 3) CMR technologists with no previous experience on CMR analysis. Both technologists underwent a 2h tutorial on how to use the software. All 3 observers analysed 20 studies, and reanalysed 10 studies 24 hours after.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of initial teaching on evaluation of left ventricular volumes by cardiovascular magnetic resonance imaging: comparison between complete and intermediate beginners and experienced observers

BACKGROUND High reproducibility and low intra- and interobserver variability are important strengths of cardiac magnetic resonance (CMR). In clinical practice a significant learning curve may however be observed. Basic CMR courses offer an average of 1.4 h dedicated to lecturing and demonstrating left ventricular (LV) function analysis. The purpose of this study was to evaluate the effect of in...

متن کامل

Real-Time Three-Dimensional Echocardiography: Characterization of Cardiac Anatomy and Function—Current Clinical Applications and Literature Review Update

Our review of real-time three-dimensional echocardiography (RT3DE) discusses the diagnostic utility of RT3DE and provides a comparison with two-dimensional echocardiography (2DE) in clinical cardiology. A Pubmed literature search on RT3DE was performed using the following key words: transthoracic, two-dimensional, three-dimensional, real-time, and left ventricular (LV) function. Articles includ...

متن کامل

CMR measures of left and right ventricular systolic performance and mortality: a factor analysis

Background Left ventricular (LV) and right ventricular (RV) systolic performance, typically measured as the ejection fraction (EF), is strongly correlated with mortality. However, CMR provides multiple measures that may also reflect systolic performance including LV volumes and cardiac outflow. We examined the predictive relationship of multiple potential measures of cardiac systolic performanc...

متن کامل

Do whole body impedance cardiography estimates of left ventricular structure, volumes and function correlate with the gold standard of cardiac magnetic resonance imaging?

Methods Consecutive patients (n = 204) undergoing a standard clinical CMR using either 1.5T or 3T MRI were enrolled. Whole-body impedance cardiography, using the Non-Invasive Cardiac System (NICaS), was performed within 14 days of the CMR. At least 5 consecutive NICaS measurements, calculated every 20 seconds, were averaged to estimate LV stroke volume (SV), cardiac output (CO) and the surrogat...

متن کامل

Compressed sensing real-time cine cardiovascular magnetic resonance: accurate assessment of left ventricular function in a single-breath-hold

BACKGROUND Cardiovascular cine magnetic resonance (CMR) accelerated by compressed sensing (CS) is used to assess left ventricular (LV) function. However, it is difficult for prospective CS cine CMR to capture the complete end-diastolic phase, which can lead to underestimation of the end-diastolic volume (EDV), stroke volume (SV), and ejection fraction (EF), compared to retrospective standard ci...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2012