BACKGROUND AND PURPOSE The angle of insonation cannot be assessed with conventional transcranial Doppler sonography. Findings in healthy control subjects suggest that the angle is relatively small in routine clinical practice. Data regarding the angle in middle cerebral artery (MCA) stenosis are scarce. In this study, the angle and its effect on flow velocity measurements were assessed with transcranial color Doppler sonography in patients with MCA stenosis. METHODS Eighteen patients (median age, 53 y; age range, 22-72 y) who satisfied qualifying criteria (eg, angiographically revealed unilateral MCA stenosis of > or =50%) were selected from 149 consecutive patients enrolled in a prospective study of transcranial color Doppler sonography and cerebral digital subtraction angiography. All had active neurologic symptoms. The angle of insonation and peak systolic and mean flow velocities in both MCAs were measured from videotapes generated at sonography. RESULTS The mean angle of insonation was 47 +/- 11 degrees (range, 19-64 degrees ) on the stenotic side and 34 +/- 18 degrees on the contralateral side (P <.05). Angle-corrected velocities were higher than uncorrected ones. Differences between angle-corrected and uncorrected peak systolic and mean flow velocities on the stenotic side were 46.6% and 45.9%, respectively, of uncorrected values. Differences between corrected and uncorrected peak systolic and mean velocities were larger on the stenotic side compared with those on the contralateral side (P <.05). CONCLUSION In patients with moderate or severe MCA stenosis, the angle of insonation can be substantial and cause large errors when flow velocities are measured without angle correction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcranial doppler sonography diagnostic value for the cerebral flow velocity changes in the interictal phase of classic migraine

Background: An imbalance of the cerebrovascular response during functional activation of the brain has been postulated as a factor in the pathophysiology of migraine. The purpose of this study was to determine the transcranial doppler sonography (TDS) diagnostic value for the cerebral flow velocity changes in the interictal phase of classic migraine. Methods: This study was carried out on 46 pa...

متن کامل

Cerebral hemodynamic in patients with major β-Thalassemia using transcranial Doppler sonography

Background: β-thalassemia, a severe form of anemia, is an inherited blood disorder characterized by growth retardation, splenomegaly, and bone abnormalities. Complications related to treatment-induced iron overload also affect the quality of life of patients with major β-thalassemia. Some recent studies indicated cerebral hemodynamic disorders and increased risk of stroke in these patients. The...

متن کامل

Results of Transcranial Doppler in Children with Sickle Cell Disease: Correlation between the Time-Averaged Mean of Maximum Velocity and Some Hematological Characteristics

Abstract Background: Transcranial Doppler ultrasonography results have not been previously studied in among Iranian sickle cell anemia patients. The present study was performed to evaluate the pattern of intracranial flow velocities among Iranian children with sickle cell anemia and the hematological parameters that can affect the time-averaged mean of maximum velocity in major intracranial...

متن کامل

Doppler angle correction in the measurement of intrarenal parameters

BACKGROUND The aim of this study was to assess differences in intrarenal artery Doppler parameters measured without and with Doppler angle correction. METHODS We retrospectively reviewed color duplex sonography in 30 normally functioning kidneys (20 native kidneys in 10 subjects and 10 transplanted kidneys in 10 subjects) performed between January 26, 2010 and July 26, 2010. There were 10 age...

متن کامل

Imaging of the basal cerebral arteries and measurement of blood velocity in adults by using transcranial real-time color flow Doppler sonography.

We report an attempt to obtain images of the basal cerebral arteries and to measure the quantitative flow velocity in these arteries from outside the skull via the color Doppler imaging method. In 25 healthy volunteers, 22-41 years old, the transducer was positioned just superior to the zygomatic arch and anterior to the external ear canal. The absolute flow velocity was calculated by dividing ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 22 9  شماره 

صفحات  -

تاریخ انتشار 2001