Microscopy with microlens arrays: high throughput, high resolution and light-field imaging.

نویسندگان

  • Antony Orth
  • Kenneth Crozier
چکیده

We demonstrate highly parallelized fluorescence scanning microscopy using a refractive microlens array. Fluorescent beads and rat femur tissue are imaged over a 5.5 mm x 5.5 mm field of view at a pixel throughput of up to 4 megapixels/s and a resolution of 706 nm. We also demonstrate the ability to extract different perspective views of a pile of microspheres.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wide-field two-dimensional multifocal optical-resolution photoacoustic-computed microscopy.

Optical-resolution photoacoustic microscopy (OR-PAM) is an emerging technique that directly images optical absorption in tissue at high spatial resolution. To date, the majority of OR-PAM systems are based on single-focused optical excitation and ultrasonic detection, limiting the wide-field imaging speed. While 1D multifocal OR-PAM (1D-MFOR-PAM) has been developed, the potential of microlens a...

متن کامل

Large - field - of - view , multi - perspective Talbot microscopy

Common microscope objectives have fields of view (FOVs) of less than a few millimeters because of limits imposed by optical aberrations. To scale up the FOVs, additional lens elements and heroic design efforts are required to compensate for the aberrations, leading to reduced transmissions and higher system costs. Such FOV limitations have thus become amajor bottleneck in microscopy for large-s...

متن کامل

High-resolution beam steering using microlens arrays.

Imaging or beam-steering systems employing a periodic array of microlenses or micromirrors suffer from diffraction problems resulting from the destructive interference of the beam segments produced by the array. Simple formulas are derived for beam steering with segmented apertures that do not suffer from diffraction problems because of the introduction of a moving linear phase shifter such as ...

متن کامل

Design and optimization of microlens array based high resolution beam steering system.

High-resolution imaging and beam steering using 3 microlens arrays (MLA) is demonstrated. Small lateral displacement of one microlens array is sufficient for large angle beam steering. A prescan lens is added to the system to overcome the discrete addressing problem associated with microlens scanning systems. A hybrid method that uses both geometrical ray tracing optimization and physical optic...

متن کامل

Large Area Full Fill Factor Microlens Arrays

Production of microlens arrays using the resist reflow technique has been extensively reported1,2. Theses arrays have fill factors approaching 75% and in lensed systems the unlensed light introduces noise into the imaging system. N T Gordon, C L Jones and D Purdy3 reported a sophisticated techniques able to create full fill, however, this is expensive. Davies and McCormick4, using optical litho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 20 12  شماره 

صفحات  -

تاریخ انتشار 2012